UM

Browse/Search Results:  1-8 of 8 Help

Selected(0)Clear Items/Page:    Sort:
A self-designed device integrated with a Fermat spiral microfluidic chip for ratiometric and automated point-of-care testing of anthrax biomarker in real samples Journal article
Lin, Xiaodong, Wu, Haotian, Zeng, Shiyu, Peng, Tao, Zhang, Pan, Wan, Xinhua, Lang, Yihan, Zhang, Biao, Jia, Yanwei, Shen, Ren, Yin, Binfeng. A self-designed device integrated with a Fermat spiral microfluidic chip for ratiometric and automated point-of-care testing of anthrax biomarker in real samples[J]. Biosensors and Bioelectronics, 2023, 230, 115283.
Authors:  Lin, Xiaodong;  Wu, Haotian;  Zeng, Shiyu;  Peng, Tao;  Zhang, Pan; et al.
Favorite | TC[WOS]:25 TC[Scopus]:24  IF:10.7/9.9 | Submit date:2023/07/20
Dpa Detection  Fermat Spiral Microfluidic Chip (Fs-mc)  Point-of-care Testing (Poct)  Ratiometric Fluorescence  Self-designed Device  
Two birds with one stone: A multifunctional nanoplatform for photothermal sensitive detection and real-time inactivation of Staphylococcus aureus with NIR responsive Cu2−XSe@Van NPs Journal article
Lin, Xiaodong, Ibarlucea, Bergoi, Peng, Tao, Shen, Ren, Li, Peiyue, Zhang, Pan. Two birds with one stone: A multifunctional nanoplatform for photothermal sensitive detection and real-time inactivation of Staphylococcus aureus with NIR responsive Cu2−XSe@Van NPs[J]. Sensors and Actuators B: Chemical, 2023, 381, 133475.
Authors:  Lin, Xiaodong;  Ibarlucea, Bergoi;  Peng, Tao;  Shen, Ren;  Li, Peiyue; et al.
Favorite | TC[WOS]:15 TC[Scopus]:16  IF:8.0/7.0 | Submit date:2023/05/02
Multifunctional Nanomaterials  Photothermal Detection  Photothermal Sterilization  Point-of-care Testing (Poct)  StaphylococcuS.aureuS.(S. aureuS.  
Nucleic acid analysis on electrowetting-based digital microfluidics Journal article
Shen, Ren, Lv, A'man, Yi, Shuhong, Wang, Ping, Mak, Pui In, Martins, Rui P., Jia, Yanwei. Nucleic acid analysis on electrowetting-based digital microfluidics[J]. TrAC - Trends in Analytical Chemistry, 2023, 158.
Authors:  Shen, Ren;  Lv, A'man;  Yi, Shuhong;  Wang, Ping;  Mak, Pui In; et al.
Favorite | TC[WOS]:9 TC[Scopus]:11  IF:11.8/12.7 | Submit date:2024/01/10
Digital microfluidics  Electrowetting  Nucleic acid amplification  Point-of-care  Sequencing  
Nucleic acid analysis on electrowetting-based digital microfluidics Review article
2023
Authors:  Shen, Ren;  Lv, A'man;  Yi, Shuhong;  Wang, Ping;  Mak, Pui In; et al.
Favorite | TC[WOS]:9 TC[Scopus]:11  IF:11.8/12.7 | Submit date:2023/02/08
Digital Microfluidics  Electrowetting  Nucleic Acid Amplification  Point-of-care  Sequencing  
Single-atom sites on perovskite chips for record-high sensitivity and quantification in SERS 钙钛矿上单原子位点实现高灵敏定量化表面拉曼增强 Journal article
Ran Feng, Qing Miao, Xiang Zhang, Peixin Cui, Cong Wang, Yibo Feng, Liyong Gan, Jiaxing Fu, Shibo Wang, Ziyi Dai, Liming Hu, Yunjing Luo, Weihai Sun, Xiaoxian Zhang, Jiawen Xiao, Jinbo Wu, Bingpu Zhou, Mingqiang Zou, Dawei He, Xiaoyuan Zhou, Xiaodong Han. Single-atom sites on perovskite chips for record-high sensitivity and quantification in SERS 钙钛矿上单原子位点实现高灵敏定量化表面拉曼增强[J]. Science China Materials, 2022, 65(6), 1601-1614.
Authors:  Ran Feng;  Qing Miao;  Xiang Zhang;  Peixin Cui;  Cong Wang; et al.
Favorite | TC[WOS]:12 TC[Scopus]:13  IF:6.8/6.6 | Submit date:2022/05/31
Charge-transfer Mechanism  In-vitro Diagnosis  Lead Halide Perovskite  Point-of-care Testing  Sers  Single-atom Site  
Automatic range adjustment of the fluorescence immunochromatographic assay based on image processing Journal article
Jiang,Ruixin, Wu,Huihuang, Yang,Jianpeng, Jiang,Haiyan, Du,Min, Vai,Mangi, Pun,Siohang, Gao,Yueming. Automatic range adjustment of the fluorescence immunochromatographic assay based on image processing[J]. SENSORS, 2019, 20(1), 209.
Authors:  Jiang,Ruixin;  Wu,Huihuang;  Yang,Jianpeng;  Jiang,Haiyan;  Du,Min; et al.
Favorite | TC[WOS]:2 TC[Scopus]:3  IF:3.4/3.7 | Submit date:2021/03/11
Fluorescence Immunochromatographic Assay  Point-of-care Testing  Automatic Range Adjustment  Image Processing  Exposure Time  
Micro- and nanofabrication NMR technologies for point-of-care medical applications – A review Review article
2019
Authors:  Dupré,Antoine;  Lei,Ka Meng;  Mak,Pui In;  Martins,Rui P.;  Peng,Weng Kung
Favorite | TC[WOS]:33 TC[Scopus]:39  IF:2.6/2.5 | Submit date:2021/03/09
Micro- And Nanofabrication In Nmr  Integrated System  Point-of-care Medical Applications  
A μNMR CMOS Transceiver Using a Butterfly-Coil Input for Integration With a Digital Microfluidic Device Inside a Portable Magnet Journal article
Ka-Meng Lei, Pui-In Mak, Man-Kay Law, Rui P. Martins. A μNMR CMOS Transceiver Using a Butterfly-Coil Input for Integration With a Digital Microfluidic Device Inside a Portable Magnet[J]. IEEE Journal of Solid-State Circuits, 2016, 51(10), 2274-2286.
Authors:  Ka-Meng Lei;  Pui-In Mak;  Man-Kay Law;  Rui P. Martins
Favorite | TC[WOS]:21 TC[Scopus]:26  IF:4.6/5.6 | Submit date:2019/02/11
Avidin  Baseband  Biological  Chemical  Cmos  Digital Microfluidic (Dmf)  Electronic Automation  Filter  Low-noise Amplifier (Lna)  Magnetic Sensing  Nuclear Magnetic Resonance (Nmr)  Point-of-care  Power Amplifier (Pa)  Radio Frequency (Rf)  Receiver (Rx)  Transceiver (Trx)  Transmitter (Tx)