UM

Browse/Search Results:  1-10 of 79 Help

Selected(0)Clear Items/Page:    Sort:
Design of galvanic coupling intra-body communication transceiver using direct sequence spread spectrum technology Journal article
Chen, W. K., Wei, Z. L., Gao, Y. M., Vasic, Z. Lucev, Cifrek, M., Vai, M.I, Du, M., Pun, S. H.. Design of galvanic coupling intra-body communication transceiver using direct sequence spread spectrum technology[J]. IEEE Access, 2020, 8, 84123-84133.
Authors:  Chen, W. K.;  Wei, Z. L.;  Gao, Y. M.;  Vasic, Z. Lucev;  Cifrek, M.; et al.
Favorite | TC[WOS]:13 TC[Scopus]:20  IF:3.4/3.7 | Submit date:2021/03/11
Intra-body Communication  Galvanic Coupling  Ibc Transceiver  Bit Error Rate  Direct Sequence Spread Spectrum (Dsss)  
Experimental Verifications of Low Frequency Path Gain ( PG ) Channel Modeling for Implantable Medical Device (IMD) Journal article
Zhang, S., Pun, S. H., Mak, P. U., Qin, Y. P., Liu, Y. H., Gao, Y. M., Vai, M. I.. Experimental Verifications of Low Frequency Path Gain ( PG ) Channel Modeling for Implantable Medical Device (IMD)[J]. IEEE Access, 2019, 11934-11945.
Authors:  Zhang, S.;  Pun, S. H.;  Mak, P. U.;  Qin, Y. P.;  Liu, Y. H.; et al.
Favorite | TC[WOS]:7 TC[Scopus]:18  IF:3.4/3.7 | Submit date:2022/09/01
Implantable Communication  Galvanic Coupling Intra-body Communication  Poisson’s Equation  Volume Conductor Theory  Implantable Medical Device (Imd)  
Heart Sound De-Noising using Wavelet and Empirical Mode Decomposition Based Thresholding Methods Conference paper
Fan, S., Sekar, B., Mak, P. U., Pun, S. H., Vai, M. I.. Heart Sound De-Noising using Wavelet and Empirical Mode Decomposition Based Thresholding Methods[C]:World Scientific, 2018, 1470-1477.
Authors:  Fan, S.;  Sekar, B.;  Mak, P. U.;  Pun, S. H.;  Vai, M. I.
Favorite |  | Submit date:2022/09/01
Heart sound  de-noising  Wavelet  
A Time-Efficient Bit Error Rate Estimation Approach Using Jitter Characteristics for Human Body Communication Channel Journal article
Li, J. W., Mak, P. U., Pun, S. H., Chen, X. M., Che, U K., Lam , C. T., Gao, Y. M., Vai, M. I., Du, M.. A Time-Efficient Bit Error Rate Estimation Approach Using Jitter Characteristics for Human Body Communication Channel[J]. IET Science, Measurement & Technology, 2017, 145-150.
Authors:  Li, J. W.;  Mak, P. U.;  Pun, S. H.;  Chen, X. M.;  Che, U K.; et al.
Favorite | TC[WOS]:4 TC[Scopus]:5  IF:1.4/1.4 | Submit date:2022/09/01
Direct Measurement of Elbow-Joint-Angle Using Galvanic Couple System Journal article
Chen, X, Barma, S, Pun, S. H., Vai, M. I., Mak, P. U.. Direct Measurement of Elbow-Joint-Angle Using Galvanic Couple System[J]. IEEE Trans. Instrum. Meas., 2017, 757-766.
Authors:  Chen, X;  Barma, S;  Pun, S. H.;  Vai, M. I.;  Mak, P. U.
Favorite |   IF:5.6/5.6 | Submit date:2022/09/01
Forearm movement  galvanic coupling system (GCS)  measurement of elbow joint angle (EJA)  
Reception Performance Ehancement of Capacitive Micromachined Ultrasonic Transducers Via Modified Membrane Structures Conference paper
Jiang, x, Yu, y, Wang, J, Liu, X, Che, U, Pun, S. H., Vai, M. I., Mak, P. U.. Reception Performance Ehancement of Capacitive Micromachined Ultrasonic Transducers Via Modified Membrane Structures[C]:Springer Nature Singapore Pte Ltd., 2017.
Authors:  Jiang, x;  Yu, y;  Wang, J;  Liu, X;  Che, U; et al.
Favorite | TC[WOS]:0  | Submit date:2022/09/01
Cmut Receiver  Sensitivity Enhancement  Slotted Membrane And Corrugated Membrane.  
A 0.45 V 147–375 nW ECG Compression Processor With Wavelet Shrinkage and Adaptive Temporal Decimation Architectures Journal article
Ieong, C. I., Li, M., Law, M. K., Mak, P. I., Vai, M. I., Martins, R. P.. A 0.45 V 147–375 nW ECG Compression Processor With Wavelet Shrinkage and Adaptive Temporal Decimation Architectures[J]. IEEE Transactions on Very Large Scale Integration Systems, 2017, 1307-1319.
Authors:  Ieong, C. I.;  Li, M.;  Law, M. K.;  Mak, P. I.;  Vai, M. I.; et al.
Favorite | TC[WOS]:25 TC[Scopus]:28  IF:2.8/2.8 | Submit date:2022/01/24
Adaptive Temporal Decimation (Atd)  Data Compression Processor  Electrocardiogram (Ecg)  Near-threshold Digital Logics  Wavelet Transform (Wt)  Wavelet Shrinkage (Ws)  
The effects of muscle stress on signal transmission in the intra-body communication Conference paper
Lin S., Zhang H.-F., Gao Y.-M., Du M., Vai M.-I.. The effects of muscle stress on signal transmission in the intra-body communication[C], 2017.
Authors:  Lin S.;  Zhang H.-F.;  Gao Y.-M.;  Du M.;  Vai M.-I.
Favorite | TC[WOS]:0 TC[Scopus]:3 | Submit date:2019/02/14
Channel Characteristics  Galvanic Coupling Intra-body Communication  Muscle Stress  
An ASIC based strip reader controller in 0.18 μm CMOS technology for lateral flow immunoassay Conference paper
Wang Z., Li G., Gao Y., Che U.K., Mak P.U., Vai M.I., Du M.. An ASIC based strip reader controller in 0.18 μm CMOS technology for lateral flow immunoassay[C], 2017.
Authors:  Wang Z.;  Li G.;  Gao Y.;  Che U.K.;  Mak P.U.; et al.
Favorite | TC[WOS]:0 TC[Scopus]:0 | Submit date:2019/02/14
Asic  Controller  Lateral Flow Immunoassay  Strip Reader  
A Lateral Flow Immunochromatographic Assay (LFIA) Strip Reader Based on Scheduler and 8051 IP Core Journal article
Vai, M. I., Mak, P. U.. A Lateral Flow Immunochromatographic Assay (LFIA) Strip Reader Based on Scheduler and 8051 IP Core[J]. Automatika, 2016, 1079-1088.
Authors:  Vai, M. I.;  Mak, P. U.
Favorite |  | Submit date:2022/09/01
FLIA  Strip reader  Scheduler  8051 IP Core