Residential College | false |
Status | 已發表Published |
A compliant constant-force mechanism with sub-Newton force and millimeter stroke output | |
Lyu, Zekui; Xu, Qingsong | |
2024-08-16 | |
Source Publication | Sensors and Actuators A-Physical |
ISSN | 0924-4247 |
Volume | 374Pages:115465 |
Abstract | Force control technology plays a pivotal role in manipulating vulnerable objects. This paper presents a new compliant mechanism with constant-force output characteristics, which can prevent force damage due to displacement overshoot. Due to its unique passive structure, it is exempted from intricate sensors and complicated controllers. The quasi-static constant-force mechanism is obtained by the parallel combination of positive- and negative-stiffness mechanisms. Such a straightforward method facilitates a rapid development and implementation process. The procedures of architectural arrangement selection, theoretical model establishment, parameter sensitivity evaluation, and multi-objective structural optimization are carried out to achieve specified constant-force characteristics. Moreover, the prototype fabrication and performance testing of a constant-force mechanism have been performed. The results demonstrate that the mechanism delivers a constant output force of 339 mN in the motion range of 1.84 mm. The constant-force feature is solely governed by the actuating displacement and is independent of driving speed and acceleration. The promising application of the constant-force mechanism has been demonstrated by manipulating small force-sensitive objects such as biological eggs. |
Keyword | Compliant Mechanism Constant-force Structure Optimization Stiffness Combination |
DOI | 10.1016/j.sna.2024.115465 |
URL | View the original |
Indexed By | SCIE |
Language | 英語English |
WOS Research Area | Engineering ; Instruments & Instrumentation |
WOS Subject | Engineering, Electrical & Electronic ; Instruments & Instrumentation |
WOS ID | WOS:001325406500001 |
Publisher | ELSEVIER SCIENCE SA, PO BOX 564, 1001 LAUSANNE, SWITZERLAND |
Scopus ID | 2-s2.0-85193450894 |
Fulltext Access | |
Citation statistics | |
Document Type | Journal article |
Collection | DEPARTMENT OF ELECTROMECHANICAL ENGINEERING |
Corresponding Author | Xu, Qingsong |
Affiliation | Department of Electromechanical Engineering, Faculty of Science and Technology, University of Macau, Avenida da Universidade, Taipa, Macao |
First Author Affilication | Faculty of Science and Technology |
Corresponding Author Affilication | Faculty of Science and Technology |
Recommended Citation GB/T 7714 | Lyu, Zekui,Xu, Qingsong. A compliant constant-force mechanism with sub-Newton force and millimeter stroke output[J]. Sensors and Actuators A-Physical, 2024, 374, 115465. |
APA | Lyu, Zekui., & Xu, Qingsong (2024). A compliant constant-force mechanism with sub-Newton force and millimeter stroke output. Sensors and Actuators A-Physical, 374, 115465. |
MLA | Lyu, Zekui,et al."A compliant constant-force mechanism with sub-Newton force and millimeter stroke output".Sensors and Actuators A-Physical 374(2024):115465. |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment