AbstractA quantitative energy leakage model was developed based on the thermography image data measured for both external and internal building surfaces. The infrared thermography images of both surfaces of doors, windows, and walls of an office building in the Hengqin Campus of University of Macao were taken at various times in a day for four seasons. The transient heat flux for sample units were obtained based on measurements of the seasonal transient local temperature differences and calculations of the effective thermal conductivity from the multiple-layer porous medium conduction model. Effects of construction unit types, orientations, and seasons were quantitatively investigated with unit transient orientation index factors. The corresponding electric energy consumption was calculated based on the air conditioning system coefficient of performance of heat pump and refrigerator cycles for different seasons. The model was validated by comparing to the electric meter records of energy consumption of the air conditioning system. The uncertainties of the predicted total building energy leakage are about 14.7%, 12.8%, 12.4%, and 15.8% for the four seasons, respectively. The differences between the predicted electric consumption and meter values are less than 13.4% and 5.4% for summer and winter, respectively. The typical daily thermal energy leakage value in winter is the highest among the four seasons. However, the daily electric energy consumption by the air conditioning system in summer and autumn is higher than that in winter. The present decomposition model for energy leakage is expected to provide a practical tool for quantitative analysis of energy leakage of buildings.
Keywordheat conductivity heat coefficient heat flux infrared thermography thermal image
Language英語English
The Source to ArticlePB_Publication
PUB ID51687
Document TypeJournal article
CollectionDEPARTMENT OF ELECTROMECHANICAL ENGINEERING
Corresponding AuthorSu, Y.
Recommended Citation
GB/T 7714
Su, Y.,Hong, F.J.,Shu, L. J.. A building unit decomposition model for energy leakage by infrared thermography image analysis[J]. Front. Energy, 2020, 1-21.
APA Su, Y.., Hong, F.J.., & Shu, L. J. (2020). A building unit decomposition model for energy leakage by infrared thermography image analysis. Front. Energy, 1-21.
MLA Su, Y.,et al."A building unit decomposition model for energy leakage by infrared thermography image analysis".Front. Energy (2020):1-21.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Su, Y.]'s Articles
[Hong, F.J.]'s Articles
[Shu, L. J.]'s Articles
Baidu academic
Similar articles in Baidu academic
[Su, Y.]'s Articles
[Hong, F.J.]'s Articles
[Shu, L. J.]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Su, Y.]'s Articles
[Hong, F.J.]'s Articles
[Shu, L. J.]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.