Abstract | Hydrogen cooler is a key equipment of the precooling unit in hydrogen refueling stations with the requirement of high heat transfer efficiency, high compactness and high pressure resistance. Printed circuit heat exchanger is a promising candidate for the hydrogen cooler due to its great performance on extremely high pressure and high temperature working environment. In this paper, a hydrogen cooler with a thermal load of 72 kW is firstly designed by using the segmented thermal design method and logarithmic mean temperature difference method. Then, the capital model of the hydrogen cooler is established to evaluate the performance using the exergoeconomic method. The results show that the operating cost, which is related to exergy destruction, accounts for 94.5% of the total cost of the hydrogen cooler. The thermal exergy destruction accounts for 92.4% of the total exergy destruction. Finally, the geometrical parameters of the channel are optimized by using the multi-objective optimization. The channel radius shows the most significant impact on the construction cost and operating cost among the three geometrical parameters. Compared with the coaxial tube evaporators, the printed circuit heat exchanger has better performance on the volume and total cost, which are reduced by 88.0% and 4.0% respectively. |
Keyword | Exergoeconomic Method Hydrogen Cooler Multi-objective Optimization Printed Circuit Heat Exchanger Segmented Design Method |
DOI | 10.1016/j.energy.2022.125455 |
URL | View the original |
Indexed By | SCIE |
Language | 英語English |
WOS Research Area | Thermodynamics ; Energy & Fuels |
WOS Subject | Thermodynamics ; Energy & Fuels |
WOS ID | WOS:000870515400003 |
Publisher | Elsevier Ltd |
Scopus ID | 2-s2.0-85139031716 |
Fulltext Access | |
Citation statistics | |
Document Type | Journal article |
Collection | DEPARTMENT OF ELECTROMECHANICAL ENGINEERING |
Affiliation | 1.Key Laboratory of Thermo-Fluid Science and Engineering, MOE, Xi'an Jiaotong University, Xi'an, 710049, China 2.Department of Electromechanical Engineering, University of Macau, Macau, 999078, China 3.Department of Mechanical Engineering, University of Nevada, Las Vegas, 89154-4027, United States |
Recommended Citation GB/T 7714 | Cheng, Yang,Li, Yingxiao,Wang, Jinghan,et al. Multi-objective optimization of printed circuit heat exchanger used for hydrogen cooler by exergoeconomic method[J]. Energy, 2023, 262. |
APA | Cheng, Yang., Li, Yingxiao., Wang, Jinghan., Tam, Lapmou., Chen, Yitung., Wang, Qiuwang., & Ma, Ting (2023). Multi-objective optimization of printed circuit heat exchanger used for hydrogen cooler by exergoeconomic method. Energy, 262. |
MLA | Cheng, Yang,et al."Multi-objective optimization of printed circuit heat exchanger used for hydrogen cooler by exergoeconomic method".Energy 262(2023). |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment