UM

Browse/Search Results:  1-10 of 16 Help

Selected(0)Clear Items/Page:    Sort:
SPECT and CT misregistration reduction in [99mTc]Tc-MAA SPECT/CT for precision liver radioembolization treatment planning Journal article
Lu,Zhonglin, Chen,Gefei, Jiang,Han, Sun,Jingzhang, Lin,Ko Han, Mok,Greta S.P.. SPECT and CT misregistration reduction in [99mTc]Tc-MAA SPECT/CT for precision liver radioembolization treatment planning[J]. European Journal of Nuclear Medicine and Molecular Imaging, 2023, 50(8), 2319-2330.
Authors:  Lu,Zhonglin;  Chen,Gefei;  Jiang,Han;  Sun,Jingzhang;  Lin,Ko Han; et al.
Favorite | TC[WOS]:5 TC[Scopus]:4  IF:8.6/8.2 | Submit date:2023/08/03
Registration  Respiratory Motion  Spect/ct  [99mtc]Tc-macroaggregated Albumin  
The effects of mismatch between SPECT and CT images on quantitative activity estimation – A simulation study Journal article
Yingqing Lyu, Gefei Chen, Zhonglin Lu, Yue Chen, Greta S.P. Mok. The effects of mismatch between SPECT and CT images on quantitative activity estimation – A simulation study[J]. Zeitschrift fur Medizinische Physik, 2022, 33(1), 54-69.
Authors:  Yingqing Lyu;  Gefei Chen;  Zhonglin Lu;  Yue Chen;  Greta S.P. Mok
Favorite | TC[WOS]:8 TC[Scopus]:7  IF:2.4/3.5 | Submit date:2022/08/05
Attenuation Correction  Misregistration  Segmentation  Spect/ct  Targeted Radionuclide Therapy  
Respiratory impacts on static and respiratory gated 99mTc-MAA SPECT/CT for liver radioembolization: A simulation study Journal article
Lu, Zhonglin, Chen, Gefei, Lyu, Yingqing, Chen, Yue, Mok, Greta S.P.. Respiratory impacts on static and respiratory gated 99mTc-MAA SPECT/CT for liver radioembolization: A simulation study[J]. Medical Physics, 2022, 49(8), 5330-5339.
Authors:  Lu, Zhonglin;  Chen, Gefei;  Lyu, Yingqing;  Chen, Yue;  Mok, Greta S.P.
Favorite | TC[WOS]:8 TC[Scopus]:7  IF:3.2/3.9 | Submit date:2022/08/05
99mtc-macroaggregated Albumin Spect/ct  Attenuation Correction  Respiratory Gated  Respiratory Motion  Segmentation  
Comparison of Projection-based and Reconstruction-based Low Dose SPECT Image Denoising Using a Conditional Generative Adversarial Network Conference paper
Mok, S. P., Zhang, Q, Sun, JZ, Du, Y. Comparison of Projection-based and Reconstruction-based Low Dose SPECT Image Denoising Using a Conditional Generative Adversarial Network[C], USA:IEEE, 2021.
Authors:  Mok, S. P.;  Zhang, Q;  Sun, JZ;  Du, Y
Favorite | TC[Scopus]:5 | Submit date:2022/07/28
Myocardial Perfusion  Spect/ct  Generative Adversarial Network, Denoising  
Evaluation of different CT maps for attenuation correction and segmentation in static 99mTc-MAA SPECT/CT for 90Y radioembolization treatment planning: A simulation study Journal article
Lu, Zhonglin, Chen, Gefei, Lin, Kuan Heng, Wu, Tung Hsin, Mok, Greta S.P.. Evaluation of different CT maps for attenuation correction and segmentation in static 99mTc-MAA SPECT/CT for 90Y radioembolization treatment planning: A simulation study[J]. Medical Physics, 2021, 48(7), 3842-3851.
Authors:  Lu, Zhonglin;  Chen, Gefei;  Lin, Kuan Heng;  Wu, Tung Hsin;  Mok, Greta S.P.
Favorite | TC[WOS]:10 TC[Scopus]:10  IF:3.2/3.9 | Submit date:2021/12/08
99mtc-macroaggregated Albumin  Attenuation Correction  Respiratory Motion  Segmentation  Spect/ct  
Effect of Respiratory Motion on Dosimetric Measurements for 99mTc-MAA SPECT/CT Conference paper
Lu, Z, Mok, S. P.. Effect of Respiratory Motion on Dosimetric Measurements for 99mTc-MAA SPECT/CT[C], 2020, S18-S18.
Authors:  Lu, Z;  Mok, S. P.
Favorite |  | Submit date:2022/07/28
Respiratory Motion  99mtc-maa  Spect/ct  
Segmentation Protocols in 99mTc-MAA SPECT/CT for 90Y Radioembolization Treatment Planning Conference paper
Mok, S. P., Lu, Z. Segmentation Protocols in 99mTc-MAA SPECT/CT for 90Y Radioembolization Treatment Planning[C]:Springer, 2020, S407-S407.
Authors:  Mok, S. P.;  Lu, Z
Favorite |  | Submit date:2022/07/28
99mtc-maa  Spect/ct  90y Radioembolization  Segmentation  
Simulation of novel scintillator crystals for brain PET Conference paper
Ozsahin,I., Uzun Ozsahin,D., Makarov,P. A., Musa,M. S., Mok,G. S.P.. Simulation of novel scintillator crystals for brain PET[C], IOP Publishing Ltd, TEMPLE CIRCUS, TEMPLE WAY, BRISTOL BS1 6BE, ENGLAND:Institute of Physics Publishing, 2020, C05024.
Authors:  Ozsahin,I.;  Uzun Ozsahin,D.;  Makarov,P. A.;  Musa,M. S.;  Mok,G. S.P.
Favorite | TC[WOS]:3 TC[Scopus]:3 | Submit date:2021/03/11
Gamma Camera, SpeCt, Pet Pet/Ct, Coronary Ct Angiography (Cta)  Medical-image Reconstruction Methods And Algorithms, Computer-aided Diagnosis  Medical-image Reconstruction Methods And Algorithms, Computer-aided Software  Scintillators, Scintillation And Light Emission Processes (Solid, Gas And Liquid Scintillators)  
Evaluation of different respiratory gating schemes for cardiac SPECT Journal article
Zhang,Duo, Pretorius,P. Hendrik, Ghaly,Michael, Zhang,Qi, King,Michael A., Mok,Greta S.P.. Evaluation of different respiratory gating schemes for cardiac SPECT[J]. Journal of Nuclear Cardiology, 2020, 27(2), 634-647.
Authors:  Zhang,Duo;  Pretorius,P. Hendrik;  Ghaly,Michael;  Zhang,Qi;  King,Michael A.; et al.
Favorite | TC[WOS]:14 TC[Scopus]:16  IF:3.0/2.9 | Submit date:2021/03/11
Cardiac Perfusion  Respiratory Gating  Simulation  Spect/ct  
Preliminary Investigation of Auto-classification of Respiratory Trace Using Convolutional Neural Network for Adaptive Respiratory Gated Myocardial Perfusion SPECT Conference paper
Mok,Greta S.P., Zhang,Qi, Sun,Jingzhang, Zhang,Duo, Pretorius,P. Hendrik, King,Michael A.. Preliminary Investigation of Auto-classification of Respiratory Trace Using Convolutional Neural Network for Adaptive Respiratory Gated Myocardial Perfusion SPECT[C], USA:IEEE, 2019, 9059744.
Authors:  Mok,Greta S.P.;  Zhang,Qi;  Sun,Jingzhang;  Zhang,Duo;  Pretorius,P. Hendrik; et al.
Favorite | TC[WOS]:0 TC[Scopus]:3 | Submit date:2021/03/11
Respiratory Gating  Convolutional Neural Network  Myocardial Perfusion  Spect/ct