UM  > Faculty of Health Sciences  > Institute of Translational Medicine
Residential Collegefalse
Status已發表Published
Noninvasive assessment of liver function reserve with fluorescent dosimetry of indocyanine green
Wu, Pei Chun1,2,3; Guo, Lun Zhang2; Yu, Shan1,4; Zeng, Ning5,6; Liu, Yu Cheng1; Yu, Jia1; Zhang, Zhiming1; Lu, Ke1; Sun, Liangyu1; Wang, Chunfei1; Chang, Yu Han2,3; Lu, Yin Lin1,3; Shen, Yu Fang7,8; Tai, Sheng9; Chuang, Yueh Hsun10; Annie Ho, Ja An11; Huang, Kai Wen12; Wu, Yao Ming13; Liu, Tzu Ming1
2022-04-01
Source PublicationBiomedical Optics Express
ISSN2156-7085
Volume13Issue:4Pages:1995-2005
Abstract

Using in vivo multiphoton fluorescent dosimetry, we demonstrate that the clearance dynamics of Indocyanine Green (ICG) in the blood can quickly reveal liver function reserve. In normal rats, the ICG retention rate was below 10% at the 15-minute post-administration; While in the rat with severe hepatocellular carcinoma (HCC), the 15-minute retention rate is over 40% due to poor liver metabolism. With a 785 nm CW laser, the fluorescence dosimeter can evaluate the liver function reserve at a 1/10 clinical dosage of ICG without any blood sampling. In the future, this low-dosage ICG 15-minute retention dosimetry can be applied for the preoperative assessment of hepatectomy or timely perioperative examination.

DOI10.1364/BOE.446749
URLView the original
Indexed BySCIE
Language英語English
WOS Research AreaBiochemistry & Molecular Biology ; Optics ; Radiology, Nuclear Medicine & Medical Imaging
WOS SubjectBiochemical Research Methods ; Optics ; Radiology, Nuclear Medicine & Medical Imaging
WOS IDWOS:000796716700002
PublisherOPTICAL SOC AMER2010 MASSACHUSETTS AVE NW, WASHINGTON, DC 20036
Scopus ID2-s2.0-85126987923
Fulltext Access
Citation statistics
Document TypeJournal article
CollectionInstitute of Translational Medicine
Faculty of Health Sciences
Corresponding AuthorLiu, Tzu Ming
Affiliation1.Institute of Translational Medicine, Faculty of Health Sciences, Ministry of Education Frontiers Science Center for Precision Oncology, University of Macau, Taipa, Macao
2.Department of Biomedical Engineering, National Taiwan University, Taipei, 10617, Taiwan
3.Molecular Imaging Center, National Taiwan University, Taipei, 10617, Taiwan
4.Department of Pathology, The Secondary Affiliated Hospital, Harbin Medical University, Harbin, 150080, China
5.First Department of Hepatobiliary Surgery, Zhujiang Hospital, Southern Medical University, Guangzhou, 510280, China
6.Guangdong Provincial Clinical and Engineering Technology Center of Digital Medicine, Guangzhou, 510280, China
7.3D Printing Medical Research Institute, Asia University, Taichung, 41354, Taiwan
8.Department of Bioinformatics and Medical Engineering, Asia University, Taichung, 41354, Taiwan
9.Department of Hepatopancreatobiliary Surgery, The Secondary Affiliated Hospital, Harbin Medical University, Harbin, 150080, China
10.Department of Anesthesiology, National Taiwan University Hospital, Taipei, 10002, Taiwan
11.Bioanalytical Chemistry and Nanobiomedicine Laboratory, Department of Biochemical Science & Technology, National Taiwan University, Taipei, 10617, Taiwan
12.Graduate Institute of Clinical Medicine, National Taiwan University College of Medicine, Taipei, 10002, Taiwan
13.Department of Surgery, National Taiwan University Hospital, College of Medicine, Taipei, 10002, Taiwan
First Author AffilicationFaculty of Health Sciences
Corresponding Author AffilicationFaculty of Health Sciences
Recommended Citation
GB/T 7714
Wu, Pei Chun,Guo, Lun Zhang,Yu, Shan,et al. Noninvasive assessment of liver function reserve with fluorescent dosimetry of indocyanine green[J]. Biomedical Optics Express, 2022, 13(4), 1995-2005.
APA Wu, Pei Chun., Guo, Lun Zhang., Yu, Shan., Zeng, Ning., Liu, Yu Cheng., Yu, Jia., Zhang, Zhiming., Lu, Ke., Sun, Liangyu., Wang, Chunfei., Chang, Yu Han., Lu, Yin Lin., Shen, Yu Fang., Tai, Sheng., Chuang, Yueh Hsun., Annie Ho, Ja An., Huang, Kai Wen., Wu, Yao Ming., & Liu, Tzu Ming (2022). Noninvasive assessment of liver function reserve with fluorescent dosimetry of indocyanine green. Biomedical Optics Express, 13(4), 1995-2005.
MLA Wu, Pei Chun,et al."Noninvasive assessment of liver function reserve with fluorescent dosimetry of indocyanine green".Biomedical Optics Express 13.4(2022):1995-2005.
Files in This Item: Download All
File Name/Size Publications Version Access License
BOE(2022)_ICG liver.(2517KB)期刊论文作者接受稿开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Wu, Pei Chun]'s Articles
[Guo, Lun Zhang]'s Articles
[Yu, Shan]'s Articles
Baidu academic
Similar articles in Baidu academic
[Wu, Pei Chun]'s Articles
[Guo, Lun Zhang]'s Articles
[Yu, Shan]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Wu, Pei Chun]'s Articles
[Guo, Lun Zhang]'s Articles
[Yu, Shan]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: BOE(2022)_ICG liver.pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.