Abstract

3-Leg Split dc link converter topology is employed as the power quality compensator in 3-phase 4-wire system to compensate the reactive and harmonic currents as well as the neutral line current by 3-dimensaional PWM techniques. However, it suffers one of the operational drawbacks that is dc link voltage variation. In the recent research, a novel mathematical model of 3 Dimensional Pulse Width Modulation (3DPWM) control technique [1] was proposed to handle the compensating control issues for 3-leg Split dc Link Inverter. But, the dc voltage variation control is not considered in [1]. In this paper, a novel 3 Dimensional PWM control technique is proposed to handle the dc Link Voltage Variation Issue in 3-level 3-leg split dc link inverter as well as the current quality compensation control. This paper described the theory of 3DPWM, the analysis of the compensating control method and dc link voltage variation issue in 3-level system. The simulation and experimental results are given to address the effectiveness of this novel control technique.

KeywordDc Voltage Imbalance Inverter Power Quality Compensator
URLView the original
Indexed BySCIE
WOS Research AreaEnergy & Fuels ; Engineering
WOS SubjectEnergy & Fuels ; Engineering, Electrical & Electronic
WOS IDWOS:000186471800070
Scopus ID2-s2.0-1542516725
Fulltext Access
Citation statistics
Document TypeConference paper
CollectionDEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING
Affiliation1.FST, University of Macau, Macau, SAR, China
2.Tsinghua University, China
First Author AffilicationFaculty of Science and Technology
Recommended Citation
GB/T 7714
Tang J.,Wong M.-C.,Han Y.-D.. DC voltage imbalance control of 3-level 3-leg split inverter system[C], 2003, 382-387.
APA Tang J.., Wong M.-C.., & Han Y.-D. (2003). DC voltage imbalance control of 3-level 3-leg split inverter system. POWER AND ENERGY SYSTEMS, PROCEEDINGS, 7, 382-387.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Tang J.]'s Articles
[Wong M.-C.]'s Articles
[Han Y.-D.]'s Articles
Baidu academic
Similar articles in Baidu academic
[Tang J.]'s Articles
[Wong M.-C.]'s Articles
[Han Y.-D.]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Tang J.]'s Articles
[Wong M.-C.]'s Articles
[Han Y.-D.]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.