UM  > Faculty of Health Sciences
Residential Collegefalse
Status已發表Published
Dose reduction in 256-slice triple rule-out CT angiography
Tsai C.-J.4; Chen L.-K.1; Mok G.S.P.5; Wu T.-H.4; Lee J.J.S.4
2011-12-01
Source PublicationRadiation Measurements
ISSN13504487
Volume46Issue:12Pages:2065-2068
Abstract

Objective: Triple rule-out (TRO) computed tomographic angiography (CTA) is a protocol which allows evaluation of coronary arteries, aorta, pulmonary arteries and adjacent intrathoracic structures for patients with acute chest pain. Retrospective ECG-gated (RGH) is generally used for TRO CTA while the feasibility of using ECG-gated tube current modulation (ETCM) or prospective ECG-triggering (PGT) protocols have not been fully investigated. The objective of this study is to investigate the potential for dose reduction through the use of ETCM and PGT in TRO CTA examination as compared with routine RGH protocols. Material and methods: All TRO CTA examinations were performed on a 256-slice CT scanner using an anthropomorphic phantom. To determine equivalent doses for different organs, thermal-luminance dosimeters (TLDs) were placed in different positions in the organs during the scanning and effective doses were calculated based on ICRP-103 guidelines. Effective doses calculated from volume CT dose index (CTDI) were also compared with those obtained from TLD measurements. Results: From the study, the mean effective dose for RGH, ETCM and PGT scanning was 21.54 mSv, 15.52 mSv and 10.75 mSv respectively. The doses for ETCM and PGT techniques were significantly reduced by 27% and 50% (p < 0.01) as compared to that for RGH. Effective doses calculated from CTDI method for three protocols were no significantly difference compared with those obtained from TLD measurements. Conclusion: Radiation dose could be efficiently reduced by applying the ETCM and PGT protocols in the 256-slice TRO CTA examinations. © 2011 Elsevier Ltd. All rights reserved.

KeywordEcg-gated Tube Current Prospectively Ecg-triggering Radiation Dose Retrospectively Ecg-gated Triple Rule-out Cta
DOI10.1016/j.radmeas.2011.06.070
URLView the original
Language英語English
WOS IDWOS:000300459400175
Scopus ID2-s2.0-82355173381
Fulltext Access
Citation statistics
Document TypeJournal article
CollectionFaculty of Health Sciences
Affiliation1.Shin-Kong Wu Ho-Su Memorial Hospital Taiwan
2.Fu Jen Catholic University
3.Hong Kong Polytechnic University
4.National Yang-Ming University Taiwan
5.Universidade de Macau
Recommended Citation
GB/T 7714
Tsai C.-J.,Chen L.-K.,Mok G.S.P.,et al. Dose reduction in 256-slice triple rule-out CT angiography[J]. Radiation Measurements, 2011, 46(12), 2065-2068.
APA Tsai C.-J.., Chen L.-K.., Mok G.S.P.., Wu T.-H.., & Lee J.J.S. (2011). Dose reduction in 256-slice triple rule-out CT angiography. Radiation Measurements, 46(12), 2065-2068.
MLA Tsai C.-J.,et al."Dose reduction in 256-slice triple rule-out CT angiography".Radiation Measurements 46.12(2011):2065-2068.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Tsai C.-J.]'s Articles
[Chen L.-K.]'s Articles
[Mok G.S.P.]'s Articles
Baidu academic
Similar articles in Baidu academic
[Tsai C.-J.]'s Articles
[Chen L.-K.]'s Articles
[Mok G.S.P.]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Tsai C.-J.]'s Articles
[Chen L.-K.]'s Articles
[Mok G.S.P.]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.