Abstract | Pinhole SPECT provides superior trade-off between resolution and detection efficiency as compared to parallel-hole collimator for imaging small field-of-view. Previously we proposed an adjustable multi-pinhole (MPH) collimator for clinical myocardial perfusion imaging (MPI) and small animal imaging (SAI) of rats, based on a clinical SPECT/CT scanner. This study aims to optimize and evaluate this MPH collimator design. For MPI and SAI, the target resolutions were set to 1 cm and 1 mm, the FOVs were 20 cm and 5 cm, and the radii-of-rotation were 25 cm and 5 cm, respectively. The maximum detector-to-detector distance for the scanner was 76 cm. Based on the work from Rentmeester et al., Nillius et al. and the system constraints, we optimized the detection efficiency and calculated the design parameters as follows: (i) MPI: 18 knife-edge pinholes with 2.61 mm aperture size, 13 cm collimator length; (ii) SAI: 4 knife-edge pinholes with aperture size of 0.41 mm, 20.8 cm collimator length. All pinholes were focused to the center of FOV. The proposed collimator was composed of two parts: a base cone with a height of 13 cm for MPI and an auxiliary cone with a height of 7.8 cm that can be combined with the base cone for SAI. The pinholes were placed in a way to utilize the whole detector, minimize projection truncation and keep the multiplexing <25%. Tc-99m point source simulations, using GATE (Geant4 Application for Emission Tomography) were performed for different imaging distances to compare the detection efficiency and resolution between low-energy-high-resolution (LEHR) parallel-hole and MPH collimator. For MPI, the measured FWHMs were 11.70 mm and 9.02 mm for LEHR and MPH respectively, while the detection efficiency of MPH had 17.5 % improvement as compared to LEHR. For SAI, the FWHMs for LEHR and MPH were 4.92 mm and 1.01 mm respectively. The new collimator has improved the imaging performance as compared to our previous design. It provides a significant improvement in resolution and detection efficiency trade-off as compared to current MPI using LEHR with extra capability for SAI. |
DOI | 10.1109/NSSMIC.2012.6551727 |
URL | View the original |
Indexed By | SCIE |
Language | 英語English |
WOS Research Area | Engineering ; Physics |
WOS Subject | Engineering, Electrical & Electronic ; Physics, Applied |
WOS ID | WOS:000326814203064 |
Scopus ID | 2-s2.0-84881573797 |
Fulltext Access | |
Citation statistics | |
Document Type | Conference paper |
Collection | DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING |
Affiliation | Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, China |
First Author Affilication | Faculty of Science and Technology |
Recommended Citation GB/T 7714 | Chin-Hong Si,Greta S. P. Mok. Design of an optimized multi-pinhole collimator for dual-purpose clinical and preclinical imaging[C], USA:IEEE, 2012, 3189-3191. |
APA | Chin-Hong Si., & Greta S. P. Mok (2012). Design of an optimized multi-pinhole collimator for dual-purpose clinical and preclinical imaging. 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC), 3189-3191. |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment