Residential College | false |
Status | 已發表Published |
Effect of transmitter and receiver electrodes configurations on the capacitive intrabody communication channel from 100 kHz to 100 MHz | |
Vasi, . Luev1; Gao, Y.M.2; Pun, S.H.3; Mak, P.U.3; Vai, M.I.3; Krois, I.1; Cifrek, M.1 | |
2014 | |
Conference Name | 15th International Conference on Biomedical Engineering, ICBME 2013 |
Source Publication | IFMBE Proceedings |
Volume | 43 |
Pages | 613-616 |
Conference Date | 124, 2013 - 127, 2013 |
Conference Place | Singapore, Singapore |
Author of Source | Springer Verlag |
Abstract | In the intrabody communication (IBC) the human body behaves as a medium that connects transmitter and receiver, which are placed directly on the skin, or are in its close proximity. The signal transmission path is closed through the human body, and the return signal path is closed capacitively through the environment. Hence, the received signal level is affected by the orientation of the transmitter with respect to the receiver, the number of ground electrodes connected to the body, the size of the receiver ground plane, and the surrounding environment. Both a transmitter and a receiver have a signal and a ground electrode, which can be connected to the human body in two ways: predominantly resistive and predominantly capacitive. In a predominantly resistive configuration, signal and ground electrodes are in a direct contact to the skin. The contact is obtained using standard Ag/AgCl electrodes, placed 2 cm apart. In a predominantly capacitive configuration, signal electrode is connected to the skin using standard Ag/AgCl electrode, and the ground electrode is a bare copper electrode placed on a plastic housing, 2 cm above the signal electrode. In this paper we measured transmission characteristics of the intrabody communication system in a frequency range from 100 kHz to 100 MHz using battery-powered network analyzer, for all four transmitterreceiver electrode configurations (resistive-resistive, capacitive- resistive, resistive-capacitive, and capacitive-capacitive), at five different distances along the arms (namely, 4 cm, 16 cm, 28 cm, 36 cm, and 120 cm). We proved that intrabody communication channel was reciprocal. The highest transmission gain was measured for capacitive-capacitive configuration, regardless of the distance between the transmitter and receiver. © Springer International Publishing Switzerland 2014. |
DOI | 10.1007/978-3-319-02913-9_156 |
Language | 英語English |
Scopus ID | 2-s2.0-84928238728 |
Fulltext Access | |
Citation statistics | |
Document Type | Conference paper |
Collection | DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING |
Affiliation | 1.University of Zagreb, Zagreb, Croatia; 2.School of Physics and Information Engineering, Fuzhou University, Fuzhou, China; 3.University of Macau, Macau, China |
Recommended Citation GB/T 7714 | Vasi, . Luev,Gao, Y.M.,Pun, S.H.,et al. Effect of transmitter and receiver electrodes configurations on the capacitive intrabody communication channel from 100 kHz to 100 MHz[C]. Springer Verlag, 2014, 613-616. |
APA | Vasi, . Luev., Gao, Y.M.., Pun, S.H.., Mak, P.U.., Vai, M.I.., Krois, I.., & Cifrek, M. (2014). Effect of transmitter and receiver electrodes configurations on the capacitive intrabody communication channel from 100 kHz to 100 MHz. IFMBE Proceedings, 43, 613-616. |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment