Detection of Smart Meter Anomaly with Error Tolerance based on Tikhonov Regularization
Chen, Lidan1,2; Lao, Kengweng2; Ma, Yongliang1; Zhang, Zhe3; Dong, Ye4; Ying, Haoji5
2021-07-26
Conference Name2021 40th Chinese Control Conference (CCC)
Source PublicationChinese Control Conference, CCC
Volume2021-July
Pages6886-6891
Conference Date26-28 July 2021
Conference PlaceShanghai
CountryChina
Abstract

Smart meters (SMs) are an important part of smart power grid, and they are also the basis for power grid operation control and trade settlement between power supply and electricity consumption. The measurement results are directly related to the security of power grid and whether the trade settlement between both sides is fair and reasonable. Therefore, it is very necessary and meaningful to carry out the detection of out-of-tolerance errors in the operation of meters. Through analyzing the data from advanced metering infrastructure (AMI) and utilizing multiple linear regression techniques, in this paper we provide a detection method for electric smart meters anomaly with error tolerance based on Tikhonov regularization and generalized cross-validation (GCV) optimization in distribution network of tree topology. To verify the effectiveness and practicality, the method proposed is applied in the actual distribution area. The results show that the proposed method did not need to calculate the network loss independently in advance, and it can find out the smart meters with error tolerance accurately.

KeywordAnomaly Detection Out-of-tolerance Errors Parameter Optimization Smart Meter Tikhonov Regularization
DOI10.23919/CCC52363.2021.9549985
URLView the original
Language英語English
Scopus ID2-s2.0-85117338995
Fulltext Access
Citation statistics
Document TypeConference paper
CollectionUniversity of Macau
Affiliation1.Guangzhou College of South China University of Technology, Guangzhou, 510800, China
2.University of Macao, 999078, Macao
3.Pazhou Lab, Guangzhou, 510335, China
4.Shanghai Electric Power Company, Shanghai, 200072, China
5.Ningbo Power Supply Company, Ningbo, 315800, China
First Author AffilicationUniversity of Macau
Recommended Citation
GB/T 7714
Chen, Lidan,Lao, Kengweng,Ma, Yongliang,et al. Detection of Smart Meter Anomaly with Error Tolerance based on Tikhonov Regularization[C], 2021, 6886-6891.
APA Chen, Lidan., Lao, Kengweng., Ma, Yongliang., Zhang, Zhe., Dong, Ye., & Ying, Haoji (2021). Detection of Smart Meter Anomaly with Error Tolerance based on Tikhonov Regularization. Chinese Control Conference, CCC, 2021-July, 6886-6891.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Chen, Lidan]'s Articles
[Lao, Kengweng]'s Articles
[Ma, Yongliang]'s Articles
Baidu academic
Similar articles in Baidu academic
[Chen, Lidan]'s Articles
[Lao, Kengweng]'s Articles
[Ma, Yongliang]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Chen, Lidan]'s Articles
[Lao, Kengweng]'s Articles
[Ma, Yongliang]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.