Residential Collegefalse
Status已發表Published
Development of a Photoelectric Adjustment System with Extended Range for Fluorescence Immunochromatographic Assay Strip Readers
Wu, Huihuang1,2; Gao, Yueming1,2; Yang, Jiejie1,2; Vai, Mangi2,4,5; Du, Min1,3; Pun, Siohang4
2021-06-01
Source PublicationIEEE Photonics Journal
ISSN1943-0655
Volume13Issue:3
Abstract

Fluorescence immunochromatographic assay (FICA) is a quantitative detection technique widely used in clinical diagnosis, environmental monitoring, and food safety. To deal with the limited applications caused by insufficient detection range, this paper proposes a photoelectric adjustment system suitable for FICA strip readers to expand its detection range. The photoelectric adjustment system is proposed based on the relationship between the excitation light intensity and the fluorescence intensity, which provides the optimal excitation light intensity and a stable baseline amplitude for the FICA strip reader. To verify the proposed system, it was applied to the strip reader we had previously developed. The results show that the linear detection range of the FICA strip reader was extended from 1.95-256 μg/mL to 1-1024 μg/mL after using the proposed method. At the same time, the accuracy of the FICA strip reader does not deteriorate and is in good comparisons with the conventional ESEQuant Lateral Flow Reader (with R2 > 0.9987). Therefore, the proposed photoelectric adjustment method and system can improve the detection range of the strip reader or other similar devices.

KeywordFluorescence Immunochromatographic Assay Photoelectric Adjustment Light Intensity Detection Range
DOI10.1109/JPHOT.2021.3075900
URLView the original
Indexed BySCIE
Language英語English
WOS Research AreaEngineering ; Optics ; Physics
WOS SubjectEngineering, Electrical & Electronic ; Optics ; Physics, Applied
WOS IDWOS:000652785300001
Scopus ID2-s2.0-85105076372
Fulltext Access
Citation statistics
Document TypeJournal article
CollectionDEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING
THE STATE KEY LABORATORY OF ANALOG AND MIXED-SIGNAL VLSI (UNIVERSITY OF MACAU)
Corresponding AuthorGao, Yueming
Affiliation1.College of Physics and Information Engineering, Fuzhou University, Fuzhou, 350108, China
2.Key Lab of Medical Instrumentation and Pharmaceutical Technology of Fujian Province, Fuzhou, 350108, China
3.Key Lab of Eco-Industrial Green Technology of Fujian Province, Nanping, 354300, China
4.State Key Laboratory of Analog and Mixed-Signal VLSI, University of Macau, 999078, Macao
5.Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, 999078, Macao
Recommended Citation
GB/T 7714
Wu, Huihuang,Gao, Yueming,Yang, Jiejie,et al. Development of a Photoelectric Adjustment System with Extended Range for Fluorescence Immunochromatographic Assay Strip Readers[J]. IEEE Photonics Journal, 2021, 13(3).
APA Wu, Huihuang., Gao, Yueming., Yang, Jiejie., Vai, Mangi., Du, Min., & Pun, Siohang (2021). Development of a Photoelectric Adjustment System with Extended Range for Fluorescence Immunochromatographic Assay Strip Readers. IEEE Photonics Journal, 13(3).
MLA Wu, Huihuang,et al."Development of a Photoelectric Adjustment System with Extended Range for Fluorescence Immunochromatographic Assay Strip Readers".IEEE Photonics Journal 13.3(2021).
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Wu, Huihuang]'s Articles
[Gao, Yueming]'s Articles
[Yang, Jiejie]'s Articles
Baidu academic
Similar articles in Baidu academic
[Wu, Huihuang]'s Articles
[Gao, Yueming]'s Articles
[Yang, Jiejie]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Wu, Huihuang]'s Articles
[Gao, Yueming]'s Articles
[Yang, Jiejie]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.