Active part minimum capacity analysis of three-phase four-wire hybrid active power filters
Cui,Xiaoxi; Lam,Chiseng; Choi,Waihei; Wong,Manchung
2013-02-10
Source PublicationDianli Xitong Zidonghua/Automation of Electric Power Systems
ISSN1000-1026
Volume37Issue:3Pages:122-128
Abstract

This paper establishes a mathematical model of three-phase four-wire center-split single-turned hybrid active power filters (HAPF) in d-q-0 coordinate. Based on this mathematical model, the filtering characteristics of the passive part of the single-tuned HAPF with and without neutral inductor are analyzed and discussed. According to the HAPF active part capacity analysis and the filtering characteristics of its passive part, the structure of the three-phase four-wire single-turned HAPF can be optimized and its minimum DC-link voltage expression can be deduced based on the general harmonic current contents of the loading. Therefore, the cost of the HAPF can be lowered by reducing its active part capacity. Finally, the correctness of the minimum DC-link voltage theory and the effectiveness of this optimized structure are verified by simulation. © 2013 State Grid Electric Power Research Institute Press.

KeywordCapacity Of Active Part D-q-0 Coordinate Hybrid Active Power Filters (Hapf) Minimum Dc-link Voltage Neutral Inductor
DOI10.7500/AEPS201107179
URLView the original
Language英語English
Scopus ID2-s2.0-84874718398
Fulltext Access
Citation statistics
Document TypeJournal article
CollectionUniversity of Macau
Corresponding AuthorCui,Xiaoxi
AffiliationFaculty of Science and Technology,University of Macau,Macau,Macao
First Author AffilicationFaculty of Science and Technology
Corresponding Author AffilicationFaculty of Science and Technology
Recommended Citation
GB/T 7714
Cui,Xiaoxi,Lam,Chiseng,Choi,Waihei,et al. Active part minimum capacity analysis of three-phase four-wire hybrid active power filters[J]. Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2013, 37(3), 122-128.
APA Cui,Xiaoxi., Lam,Chiseng., Choi,Waihei., & Wong,Manchung (2013). Active part minimum capacity analysis of three-phase four-wire hybrid active power filters. Dianli Xitong Zidonghua/Automation of Electric Power Systems, 37(3), 122-128.
MLA Cui,Xiaoxi,et al."Active part minimum capacity analysis of three-phase four-wire hybrid active power filters".Dianli Xitong Zidonghua/Automation of Electric Power Systems 37.3(2013):122-128.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Cui,Xiaoxi]'s Articles
[Lam,Chiseng]'s Articles
[Choi,Waihei]'s Articles
Baidu academic
Similar articles in Baidu academic
[Cui,Xiaoxi]'s Articles
[Lam,Chiseng]'s Articles
[Choi,Waihei]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Cui,Xiaoxi]'s Articles
[Lam,Chiseng]'s Articles
[Choi,Waihei]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.