UM  > Institute of Chinese Medical Sciences
Residential Collegefalse
Status已發表Published
Detection of base excision repair enzyme activity using a luminescent G-quadruplex selective switch-on probe
Leung K.-H.1; He H.-Z.1; Ma V.P.-Y.1; Zhong H.-J.2; Chan D.S.-H.1; Zhou J.3,4; Mergny J.-L.3,4; Leung C.-H.2; Ma D.-L.1
2013
Source PublicationChemical Communications
ISSN13597345
Volume49Issue:50Pages:5630
Abstract

We report herein a simple and convenient luminescent assay for detection of base excision repair enzyme activity using an Ir(iii) complex as a G-quadruplex selective probe. Using uracil-DNA glycosylase (UDG) as a model enzyme, the assay achieved high sensitivity and selectivity for UDG over other tested enzymes. The utility of the assay for screening potential UDG inhibitors was also demonstrated. © 2013 The Royal Society of Chemistry.

KeywordDna Mismatch Repair Complexes Mechanisms Assay
DOI10.1039/c3cc41129j
URLView the original
Indexed BySCIE
Language英語English
WOS Research AreaChemistry
WOS SubjectChemistry, Multidisciplinary
WOS IDWOS:000319511900003
PublisherROYAL SOC CHEMISTRYTHOMAS GRAHAM HOUSE, SCIENCE PARK, MILTON RD, CAMBRIDGE CB4 0WF, CAMBS, ENGLAND
The Source to ArticleScopus
Scopus ID2-s2.0-84878659357
Fulltext Access
Citation statistics
Document TypeJournal article
CollectionInstitute of Chinese Medical Sciences
Corresponding AuthorLeung C.-H.; Ma D.-L.
Affiliation1.Department of Chemistry, Hong Kong Baptist University, Kowloon Tong, Hong Kong, China
2.State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences, University of Macau, Macao, China
3.INSERM, U869, IECB, F-33600, Pessac, France
4.Univ. Bordeaux, ARNA Laboratory, F-33000, Bordeaux, France
Corresponding Author AffilicationInstitute of Chinese Medical Sciences
Recommended Citation
GB/T 7714
Leung K.-H.,He H.-Z.,Ma V.P.-Y.,et al. Detection of base excision repair enzyme activity using a luminescent G-quadruplex selective switch-on probe[J]. Chemical Communications, 2013, 49(50), 5630.
APA Leung K.-H.., He H.-Z.., Ma V.P.-Y.., Zhong H.-J.., Chan D.S.-H.., Zhou J.., Mergny J.-L.., Leung C.-H.., & Ma D.-L. (2013). Detection of base excision repair enzyme activity using a luminescent G-quadruplex selective switch-on probe. Chemical Communications, 49(50), 5630.
MLA Leung K.-H.,et al."Detection of base excision repair enzyme activity using a luminescent G-quadruplex selective switch-on probe".Chemical Communications 49.50(2013):5630.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Leung K.-H.]'s Articles
[He H.-Z.]'s Articles
[Ma V.P.-Y.]'s Articles
Baidu academic
Similar articles in Baidu academic
[Leung K.-H.]'s Articles
[He H.-Z.]'s Articles
[Ma V.P.-Y.]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Leung K.-H.]'s Articles
[He H.-Z.]'s Articles
[Ma V.P.-Y.]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.