UM
Status已發表Published
A Calibration Scheme for Stability of Self-biased Ring Amplifier
Yan, Rongshen; Chan, Chi-Hang; Sin, Sai-Weng; Seng-Pan, U.; Martins, R. P.; Wang, ZH; Xie, WH
2017
Conference Name2017 6TH INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS AND COMPUTER SCIENCE (ICAMCS 2017)
Pages226-235
Publication Place703 KILMAR CRES, OTTAWA, ONTARIO K2T 0B1, CANADA
PublisherCLAUSIUS SCIENTIFIC PR INC
AbstractThis paper presents a calibration scheme to enhance the robustness of the Self Biased Ring Amplifier (SBRA) under PVT variations. As the ring amplifier is developed based on a ring oscillator structure, it can easily oscillate under PVT variations. The proposed calibration method utilizes an Oscillation Detection Circuit (ODC) with a close loop control of a Programmable Resistor Array Circuit (PRAC) to adjust the dead-zone (stability region), thus stabilizing the SBRA. The introduced ODC and PRAC have little influence on the power efficiency as well as hardware overhead. Based on a 1.5 bit/stage Multiplying Digital to Analog Converter (MDAC) circuit setup, the simulation shows that the proposed method can stabilize the ring amplifier in the range of 0 degrees C to 85 degrees C at all corners.
KeywordCalibration Self-biased Ring Amplifier PVT Variations Oscillation Detection Programmable Resistor
DOI10.23977/icames.2017.1029
URLView the original
Indexed ByCPCI
Language英語English
WOS Research AreaEngineering ; Materials Science ; Mathematics
WOS SubjectEngineering, Mechanical ; Materials Science, Multidisciplinary ; Mathematics, Applied
WOS IDWOS:000432428300029
The Source to ArticleWOS
Fulltext Access
Citation statistics
Document TypeConference paper
CollectionUniversity of Macau
Recommended Citation
GB/T 7714
Yan, Rongshen,Chan, Chi-Hang,Sin, Sai-Weng,et al. A Calibration Scheme for Stability of Self-biased Ring Amplifier[C], 703 KILMAR CRES, OTTAWA, ONTARIO K2T 0B1, CANADA:CLAUSIUS SCIENTIFIC PR INC, 2017, 226-235.
APA Yan, Rongshen., Chan, Chi-Hang., Sin, Sai-Weng., Seng-Pan, U.., Martins, R. P.., Wang, ZH., & Xie, WH (2017). A Calibration Scheme for Stability of Self-biased Ring Amplifier. , 226-235.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Yan, Rongshen]'s Articles
[Chan, Chi-Hang]'s Articles
[Sin, Sai-Weng]'s Articles
Baidu academic
Similar articles in Baidu academic
[Yan, Rongshen]'s Articles
[Chan, Chi-Hang]'s Articles
[Sin, Sai-Weng]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Yan, Rongshen]'s Articles
[Chan, Chi-Hang]'s Articles
[Sin, Sai-Weng]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.