Residential College | false |
Status | 已發表Published |
A 220-MHz Bondwire-Based Fully-Integrated KY Converter With Fast Transient Response Under DCM Operation | |
Zeng, Wen-Liang; Lam, Chi-Seng; Sin, Sai-Weng; Maloberti, Franco; Wong, Man-Chung; Martins, Rui Paulo | |
2018-11 | |
Source Publication | IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS |
Volume | 65Issue:11Pages:3984-3995 |
Abstract | This paper presents a 220-MHz pulse width modulation (PWM) fully integrated KY dc-dc step-up converter utilizing bondwire as power inductor, with discontinuous conduction mode (DCM) calibration control. We develop the first DCM closed-loop PWM controller for the KY converter, including: 1) its parameter design; 2) a DCM closed-loop voltage mode control with Type II compensator; 3) a zero current detection method to activate DCM control; and 4) a DCM calibration loop. Fabricated in 65-nm CMOS, the designed KY converter core occupies 0.93 mm(2) and achieves an output conversion range of 1.5-2 V from a 1.2-V input. The measured peak efficiency is 75.2% at 97.5 mW. With a 500-ps rising/falling time of the load current step (56 mA), the undershoot/overshoot is 245/205 mV at 146-/140-ns recovery time, and the dc-dc converter achieves a settling time per load transient step of 2.6 ns/mA, which is competitive with the state-of-the-art boost converters. |
Keyword | Fully Integrated Ky Converter Boost Converter Pwm Discontinuous Conduction Mode (Dcm) Zero Current Detection (Zcd) Load Transient Response Voltage Ripple Bondwire Inductor |
DOI | 10.1109/TCSI.2018.2854370 |
URL | View the original |
Indexed By | SCIE ; EI |
Language | 英語English |
WOS Research Area | Engineering |
WOS Subject | Engineering, Electrical & Electronic |
WOS ID | WOS:000446922100035 |
Publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC |
The Source to Article | WOS |
Scopus ID | 2-s2.0-85051377421 |
Fulltext Access | |
Citation statistics | |
Document Type | Journal article |
Collection | Faculty of Science and Technology INSTITUTE OF MICROELECTRONICS DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING |
Corresponding Author | Lam, Chi-Seng |
Recommended Citation GB/T 7714 | Zeng, Wen-Liang,Lam, Chi-Seng,Sin, Sai-Weng,et al. A 220-MHz Bondwire-Based Fully-Integrated KY Converter With Fast Transient Response Under DCM Operation[J]. IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2018, 65(11), 3984-3995. |
APA | Zeng, Wen-Liang., Lam, Chi-Seng., Sin, Sai-Weng., Maloberti, Franco., Wong, Man-Chung., & Martins, Rui Paulo (2018). A 220-MHz Bondwire-Based Fully-Integrated KY Converter With Fast Transient Response Under DCM Operation. IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 65(11), 3984-3995. |
MLA | Zeng, Wen-Liang,et al."A 220-MHz Bondwire-Based Fully-Integrated KY Converter With Fast Transient Response Under DCM Operation".IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS 65.11(2018):3984-3995. |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment