Residential College | false |
Status | 已發表Published |
Respiratory average CT for attenuation correction in myocardial perfusion SPECT/CT | |
Zhang, Duo1; Yang, Bang-Hung2,3; Wu, Nien Yun2,3; Mok, Greta Seng Peng1 | |
2017-02 | |
Source Publication | ANNALS OF NUCLEAR MEDICINE |
ISSN | 0914-7187 |
Volume | 31Issue:2Pages:172-180 |
Abstract | Cine average CT (CACT) and interpolated average CT (IACT) have been proposed to improve attenuation correction (AC) for PET/CT in oncologic and cardiac studies. This study aims to evaluate their effectiveness on myocardial perfusion SPECT/CT using computer simulation and physical phantom experiments. |
Keyword | Spect/ct Myocardial Perfusion Attenuation Correction Respiratory Artifacts |
DOI | 10.1007/s12149-016-1144-1 |
URL | View the original |
Indexed By | SCIE |
Language | 英語English |
WOS Research Area | Radiology, Nuclear Medicine & Medical Imaging |
WOS Subject | Radiology, Nuclear Medicine & Medical Imaging |
WOS ID | WOS:000394218100008 |
Publisher | SPRINGER |
The Source to Article | WOS |
Scopus ID | 2-s2.0-84996564517 |
Fulltext Access | |
Citation statistics | |
Document Type | Journal article |
Collection | Faculty of Health Sciences DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING |
Corresponding Author | Mok, Greta Seng Peng |
Affiliation | 1.Biomedical Imaging Laboratory, Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Avenida da Universidade, Taipa, Macau SAR, China 2.Department of Biomedical Imaging and Radiological Sciences, National Yang Ming University, Taipei, Taiwan 3.Department of Nuclear Medicine, National PET/Cyclotron Center, Taipei Veterans General Hospital, Taipei, Taiwan |
First Author Affilication | Faculty of Science and Technology |
Corresponding Author Affilication | Faculty of Science and Technology |
Recommended Citation GB/T 7714 | Zhang, Duo,Yang, Bang-Hung,Wu, Nien Yun,et al. Respiratory average CT for attenuation correction in myocardial perfusion SPECT/CT[J]. ANNALS OF NUCLEAR MEDICINE, 2017, 31(2), 172-180. |
APA | Zhang, Duo., Yang, Bang-Hung., Wu, Nien Yun., & Mok, Greta Seng Peng (2017). Respiratory average CT for attenuation correction in myocardial perfusion SPECT/CT. ANNALS OF NUCLEAR MEDICINE, 31(2), 172-180. |
MLA | Zhang, Duo,et al."Respiratory average CT for attenuation correction in myocardial perfusion SPECT/CT".ANNALS OF NUCLEAR MEDICINE 31.2(2017):172-180. |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment