UM  > Faculty of Science and Technology
Residential Collegefalse
Status已發表Published
Mapping the aqueous outflow system of an intact mouse eye using multiphoton spectral imaging
Tim Lei1; xianzeng Zhang1; Nenrong Liu1; Peng Un Mak2; Sio Hang Pun2; Mang I Vai2; Omid Masihzadeh3; Malik Y Kahook3; David A Ammar3
2015-06
Source PublicationInvestigative Ophthalmology & Visual Science
ISSN0146-0404
Volume56Issue:7
Abstract

Purpose: Elevated intraocular pressure due to dysfunction of the aqueous outflow system (AOS) is a major risk factor for developing open angle glaucoma. We propose to use multiphoton spectral imaging techniques to quantify the structural and functional changes of the AOS to better understand the development and progression of the disease.

Methods: Multiphoton spectral microscopy techniques, including two-photon autofluorescence (TPAF) and second harmonic generation (SHG), were used to image the structures of the AOS in freshly enucleated mouse eyes. To optimize optical penetration through the highly scattering scleral tissue, the excitation laser was tuned to longer infrared wavelengths (≥ 930nm) without appreciable signal degradation. SHG was used to identify the scleral and corneal collagen structures. In separate experiments, TPAF was used to identify blood vessels perfused with fluorescent-conjugated dextran (150KDa) or AOS perfused with fluorescein.

Results: An interconnected system of anterior chamber structures including Schlemm’s canal (SC), collector channels (CC) and perilimbal superficial vessels were identified using the absence of SHG signal from the scleral collagen. The collagen of the trabecular meshwork (TM) was detected proximal to SC. The diameter of the SC at the TM was ~61 µm and tapered down to ~11 µm where it connected to CC. The average depth of the SC was ~17 µm. The diameters of the CC and perilimbal superficial vessels were ~18.5 µm and ~15.3 µm respectively. None of these structures labelled with fluorescent dextran in cardiac perfusion experiments, indicating that they were not episcleral veins.

Conclusions: Detailed structures of the mouse TM, SC, CC, perilimbal superficial vessels and episcleral veins were identified and quantified using TPAF and SHG. These results validate the use of longer excitation wavelength (≥930nm) for deeper penetration of intact ocular tissues in multiphoton microscopy.

Indexed BySCIE
Language英語English
WOS Research AreaOphthalmology
WOS SubjectOphthalmology
WOS IDWOS:000362891100129
Fulltext Access
Citation statistics
Document TypeJournal article
CollectionFaculty of Science and Technology
INSTITUTE OF MICROELECTRONICS
DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING
Affiliation1.Electrical Engineering, University of Colorado Denver, Denver, CO
2.Electrical and Computer Engineering, University of Macau, Macau, Macao
3.Ophthalmology, University of Colorado Denver, Aurora, CO
Recommended Citation
GB/T 7714
Tim Lei,xianzeng Zhang,Nenrong Liu,et al. Mapping the aqueous outflow system of an intact mouse eye using multiphoton spectral imaging[J]. Investigative Ophthalmology & Visual Science, 2015, 56(7).
APA Tim Lei., xianzeng Zhang., Nenrong Liu., Peng Un Mak., Sio Hang Pun., Mang I Vai., Omid Masihzadeh., Malik Y Kahook., & David A Ammar (2015). Mapping the aqueous outflow system of an intact mouse eye using multiphoton spectral imaging. Investigative Ophthalmology & Visual Science, 56(7).
MLA Tim Lei,et al."Mapping the aqueous outflow system of an intact mouse eye using multiphoton spectral imaging".Investigative Ophthalmology & Visual Science 56.7(2015).
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Tim Lei]'s Articles
[xianzeng Zhang]'s Articles
[Nenrong Liu]'s Articles
Baidu academic
Similar articles in Baidu academic
[Tim Lei]'s Articles
[xianzeng Zhang]'s Articles
[Nenrong Liu]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Tim Lei]'s Articles
[xianzeng Zhang]'s Articles
[Nenrong Liu]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.