UM  > Institute of Chinese Medical Sciences
Residential Collegefalse
Status已發表Published
Poly(epsilon-caprolactone)-containing graft copolymers for ratiometric extracellular oxygen sensing
Zou, Xianshao; Pan, Tingting; Jiang, Jiapei; Li, Gang; Song, Cheng; Sun, Ruofan; Yang, Ziyun; Sun, Dazhi; Hou, Chunhui; Chen, Meiwan; Tian, Yanqing
2017-09
Source PublicationSENSORS AND ACTUATORS B-CHEMICAL
ISSN0925-4005
Volume248Pages:108-118
Abstract

A graft copolymer composed of poly(epsilon-caprolactone) as a hydrophobic chain and poly(N-(2hydroxypropyl)methacrylamide) as a hydrophilic segment with an internal reference probe for oxygen sensing was prepared. Highly efficient platinum(II)meso-tetra(pentafluorophenyl)porphine (PtTFPP) was used as a typical oxygen probe. Although PtTFPP was highly efficient, it is hydrophobic, limiting its direct application for oxygen sensing in biological conditions. By using the amphiphilic graft copolymer, PTTFPP was successfully incorporated into the micelles formed by this polymer to not only enable the application of PtTFPP for biosensing in medium but also retain its high efficiency. The quantum efficiency of PtTFPP in the micelle solution under nitrogen can reach as high as 0.20. The PtTFPP-containing micelles were tested for high throughput cell respiration and bacteria detection. The influence of an antibiotic, antimycin as a representative example, on cell respiration was also studied. For achieving high accurate sensing, an internal built-in reference probe with aggregation induced emission properties were also polymerized in the graft copolymer. This study demonstrated that the graft polymer approach is a good way to enable highly efficient and hydrophobic oxygen probes for biosensing. (C) 2017 Elsevier B.V. All rights reserved.

KeywordOxygen Sensor Ratiometric Sensor Graft Copolymer Oxygen Consumption Micelles
DOI10.1016/j.snb.2017.03.126
URLView the original
Indexed BySCIE
Language英語English
WOS Research AreaChemistry ; Electrochemistry ; Instruments & Instrumentation
WOS SubjectChemistry, Analytical ; Electrochemistry ; Instruments & Instrumentation
WOS IDWOS:000403772200015
PublisherELSEVIER SCIENCE SA
The Source to ArticleWOS
Scopus ID2-s2.0-85016794128
Fulltext Access
Citation statistics
Document TypeJournal article
CollectionInstitute of Chinese Medical Sciences
Recommended Citation
GB/T 7714
Zou, Xianshao,Pan, Tingting,Jiang, Jiapei,et al. Poly(epsilon-caprolactone)-containing graft copolymers for ratiometric extracellular oxygen sensing[J]. SENSORS AND ACTUATORS B-CHEMICAL, 2017, 248, 108-118.
APA Zou, Xianshao., Pan, Tingting., Jiang, Jiapei., Li, Gang., Song, Cheng., Sun, Ruofan., Yang, Ziyun., Sun, Dazhi., Hou, Chunhui., Chen, Meiwan., & Tian, Yanqing (2017). Poly(epsilon-caprolactone)-containing graft copolymers for ratiometric extracellular oxygen sensing. SENSORS AND ACTUATORS B-CHEMICAL, 248, 108-118.
MLA Zou, Xianshao,et al."Poly(epsilon-caprolactone)-containing graft copolymers for ratiometric extracellular oxygen sensing".SENSORS AND ACTUATORS B-CHEMICAL 248(2017):108-118.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Zou, Xianshao]'s Articles
[Pan, Tingting]'s Articles
[Jiang, Jiapei]'s Articles
Baidu academic
Similar articles in Baidu academic
[Zou, Xianshao]'s Articles
[Pan, Tingting]'s Articles
[Jiang, Jiapei]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Zou, Xianshao]'s Articles
[Pan, Tingting]'s Articles
[Jiang, Jiapei]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.