Voltage mode controller design and experimental verification of a three-phase capacitive-coupling grid connected inverter in PV system | |
Chao C.-W.; Choi W.-H.; Lam C.-S.; Wong C.-K.; Dai N.; Wong M.-C. | |
2018-10 | |
Conference Name | 44th Annual Conference of the IEEE Industrial-Electronics-Society (IECON) |
Source Publication | Proceedings: IECON 2018 - 44th Annual Conference of the IEEE Industrial Electronics Society |
Pages | 4404-4408 |
Conference Date | OCT 20-23, 2018 |
Conference Place | Washington, DC |
Abstract | In this paper, a voltage mode controller called Quasi proportional-resonant (Quasi-PR) controller has adopted in a three-phase capacitive-coupling grid-connected inverter (CGCI) PV system. Under CGCI structure, the function of the inverter is to compensate the reactive power as well as generate the active power to the grid with low operating dc-link voltage. The Quasi-PR controller could be effectively applied in a sinusoidal current tracking problem with low steady-state error and suppressing the system voltage disturbance at the fundamental frequency. Experimental results are given to verify the effectiveness of the suggested controller in CGCI. |
Keyword | Cgci Hysteresis Pulse Width Modulation (Pwm) Quasi-pr Reactive Power |
DOI | 10.1109/IECON.2018.8591553 |
URL | View the original |
Indexed By | CPCI-S ; EI |
Language | 英語English |
WOS Research Area | Engineering |
WOS ID | WOS:000505811104053 |
Scopus ID | 2-s2.0-85061535426 |
Fulltext Access | |
Citation statistics | |
Document Type | Conference paper |
Collection | INSTITUTE OF MICROELECTRONICS DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING |
Corresponding Author | Lam C.-S. |
Affiliation | University of Macau |
First Author Affilication | University of Macau |
Corresponding Author Affilication | University of Macau |
Recommended Citation GB/T 7714 | Chao C.-W.,Choi W.-H.,Lam C.-S.,et al. Voltage mode controller design and experimental verification of a three-phase capacitive-coupling grid connected inverter in PV system[C], 2018, 4404-4408. |
APA | Chao C.-W.., Choi W.-H.., Lam C.-S.., Wong C.-K.., Dai N.., & Wong M.-C. (2018). Voltage mode controller design and experimental verification of a three-phase capacitive-coupling grid connected inverter in PV system. Proceedings: IECON 2018 - 44th Annual Conference of the IEEE Industrial Electronics Society, 4404-4408. |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment