Residential College | false |
Status | 已發表Published |
A 4.06 mW 10-bit 150 MS/s SAR ADC with 1.5-bit/cycle Operation for Medical Imaging Applications | |
Sunny S.1; Chen Y.2; Boon C.C.1 | |
2018-06-01 | |
Source Publication | IEEE Sensors Journal |
ISSN | 1530-437X |
Volume | 18Issue:11Pages:4553-4560 |
Abstract | This paper reports a 10-bit 150 MS/s successive approximation register analog-to-digital converter with binary-scaled redundancy-facilitated error correction technique. The proposed 1.5-bit/cycle technique with built-in capacitive digital-to-analog converter (CDAC) redundancy, corrects multiple erroneous decisions in a total of nine conversion cycles. The proposed binary-scaled redundancy provides a 12.5% error tolerance range for the incomplete CDAC voltage settling. The digital error-correction logic circuit presented uses a bit-overlap-and-add technique. The prototype chip was fabricated in 65-nm CMOS technology and occupies chip area of 0.038 mm. It consumes 4.06 mW from a 1.2 V supply, achieving the Nyquist signal-to-noise-and-distortion ratio of 57.81 dB and the effective number of bits of 9.31-bit at an operating frequency of 150 MS/s, corresponding to the figure-of-merit of 42.6 fJ/ conversion-step. |
Keyword | 1.5-bit/cycle Adc Capacitive Digital-to-analog Converter (Cdac) Cmos Error Correction Low Power Medical Imaging Redundancy Sar Successive Approximation Register |
DOI | 10.1109/JSEN.2018.2825400 |
URL | View the original |
Indexed By | SCIE |
Language | 英語English |
WOS Research Area | Instruments & Instrumentation ; Physics ; Engineering |
WOS Subject | Engineering, Electrical & Electronic ; Instruments & Instrumentation ; Physics, Applied |
WOS ID | WOS:000432017100026 |
Scopus ID | 2-s2.0-85045328212 |
Fulltext Access | |
Citation statistics | |
Document Type | Journal article |
Collection | INSTITUTE OF MICROELECTRONICS |
Corresponding Author | Chen Y. |
Affiliation | 1.Nanyang Technological University 2.Universidade de Macau |
Corresponding Author Affilication | University of Macau |
Recommended Citation GB/T 7714 | Sunny S.,Chen Y.,Boon C.C.. A 4.06 mW 10-bit 150 MS/s SAR ADC with 1.5-bit/cycle Operation for Medical Imaging Applications[J]. IEEE Sensors Journal, 2018, 18(11), 4553-4560. |
APA | Sunny S.., Chen Y.., & Boon C.C. (2018). A 4.06 mW 10-bit 150 MS/s SAR ADC with 1.5-bit/cycle Operation for Medical Imaging Applications. IEEE Sensors Journal, 18(11), 4553-4560. |
MLA | Sunny S.,et al."A 4.06 mW 10-bit 150 MS/s SAR ADC with 1.5-bit/cycle Operation for Medical Imaging Applications".IEEE Sensors Journal 18.11(2018):4553-4560. |
Files in This Item: | There are no files associated with this item. |