UM  > INSTITUTE OF MICROELECTRONICS
Residential Collegefalse
Status已發表Published
Quasi-Static Field Modeling and Validation for Intra-Body Communication
Yue Ming Gao1,3; Sio Hang Pun1,2; Min Du1,3; Mang I Vai1,2; Peng Un Mak1,2
2009-12-31
Conference Name3rd International Conference on Bioinformatics and Biomedical Engineering
Source Publication3rd International Conference on Bioinformatics and Biomedical Engineering, iCBBE 2009
Pages1389-1392
Conference Date11-13 June 2009
Conference PlaceBeijing, PEOPLES R CHINA
CountryChina
PublisherIEEE
Abstract

Intra-body Communication (IBC) is an emerging and interesting communication technique in recent years. Utilizing the conductive property of human body, IBC employs human body as communication medium for transmitting electrical signals. As a result, electromagnetic interference can be greatly reduced for devices communicated within human body. These advantages are significant for home health care system, which abundant of interconnected cables are inevitable.

In this paper, a preliminary quasi-static electromagnetic model for IBC based on the galvanic method is developed. This model attempts to provide insight of transmitting electrical signal through human body and forms a basis for developing IBC applications. Furthermore, this model is capable of providing the potential distribution in different type of biology tissues with different conductivities at low frequency. Finally, experimental measurements are conducted for validating the correctness of the model. 

KeywordGalvanic Coupling Home Health Care Intra-body Communication Maxwell Equations Model
DOI10.1109/ICBBE.2009.5163276
URLView the original
Indexed BySCIE
Language英語English
WOS Research AreaEngineering
WOS SubjectEngineering, Biomedical ; Engineering, Electrical & Electronic
WOS IDWOS:000286342800344
Scopus ID2-s2.0-72749124738
Fulltext Access
Citation statistics
Document TypeConference paper
CollectionINSTITUTE OF MICROELECTRONICS
DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING
Affiliation1.Key Laboratory of Medical Instrumentation & Pharmaceutical Technology, Fu jian Province, CHINA
2.Department of Electrical and Electronics Engineering, Faculty of Science and Technology, University of Macau, Macau SAR, CHINA
3.Institute of Precision Instrument, Fu zhou University, Fu zhou, CHINA
Recommended Citation
GB/T 7714
Yue Ming Gao,Sio Hang Pun,Min Du,et al. Quasi-Static Field Modeling and Validation for Intra-Body Communication[C]:IEEE, 2009, 1389-1392.
APA Yue Ming Gao., Sio Hang Pun., Min Du., Mang I Vai., & Peng Un Mak (2009). Quasi-Static Field Modeling and Validation for Intra-Body Communication. 3rd International Conference on Bioinformatics and Biomedical Engineering, iCBBE 2009, 1389-1392.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Yue Ming Gao]'s Articles
[Sio Hang Pun]'s Articles
[Min Du]'s Articles
Baidu academic
Similar articles in Baidu academic
[Yue Ming Gao]'s Articles
[Sio Hang Pun]'s Articles
[Min Du]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Yue Ming Gao]'s Articles
[Sio Hang Pun]'s Articles
[Min Du]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.