Residential Collegefalse
Status已發表Published
Fault detection and isolation and fault tolerant control of wind turbines using set-valued observers
P. Casau1; P. Rosa1; S.M. TabatabaeipourS.M.2; C. Silvestre1,3
2016-04-23
Conference Name8th IFAC Symposium on Fault Detection, Supervision and Safety of Technical Processes (SAFEPROCESS)
Source PublicationIFAC Proceedings Volumes (IFAC-PapersOnline)
Volume45
Issue20 PART 1
Pages120-125
Conference Date8th IFAC Symposium on Fault Detection, Supervision and Safety of Technical Processes (SAFEPROCESS)
Conference PlaceMexico City
CountryMexico
Author of SourceElsevier
Abstract

Research on wind turbine Operations & Maintenance (O&M) procedures is critical to the expansion of Wind Energy Conversion systems (WEC). In order to reduce O&M costs and increase the lifespan of the turbine, we study the application of Set-Valued Observers (SVO) to the problem of Fault Detection and Isolation (FDI) and Fault Tolerant Control (FTC) of wind turbines, by taking advantage of the recent advances in SVO theory for model invalidation. A simple wind turbine model is presented along with possible faulty scenarios. The FDI algorithm is built on top of the described model, taking into account process disturbances, uncertainty and sensor noise. The FTC strategy takes advantage of the proposed FDI algorithm, enabling the controller reconfiguration shortly after fault events. Additionally, a robust controller is designed so as to increase the wind turbine's performance during low severity faults. Finally, the FDI algorithm is assessed within a publicly available benchmark model, using Monte-Carlo simulation runs.

DOI10.3182/20120829-3-MX-2028.00214
URLView the original
Language英語English
Scopus ID2-s2.0-84867069688
Fulltext Access
Citation statistics
Document TypeConference paper
CollectionDEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING
Corresponding AuthorP. Casau
Affiliation1.Institute for Systems and Robotics - Instituto Superior T ́ecnico, Av.Rovisco Pais, 1, 1049-001 Lisboa, Portuga
2.Aalborg University, 9220 Aalborg East, Denmark
3.Faculty for Science and Technology, University of Macau, Taipa,Macau
Recommended Citation
GB/T 7714
P. Casau,P. Rosa,S.M. TabatabaeipourS.M.,et al. Fault detection and isolation and fault tolerant control of wind turbines using set-valued observers[C]. Elsevier, 2016, 120-125.
APA P. Casau., P. Rosa., S.M. TabatabaeipourS.M.., & C. Silvestre (2016). Fault detection and isolation and fault tolerant control of wind turbines using set-valued observers. IFAC Proceedings Volumes (IFAC-PapersOnline), 45(20 PART 1), 120-125.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[P. Casau]'s Articles
[P. Rosa]'s Articles
[]'s Articles
Baidu academic
Similar articles in Baidu academic
[P. Casau]'s Articles
[P. Rosa]'s Articles
[S.M. Tabatabaei...]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[P. Casau]'s Articles
[P. Rosa]'s Articles
[S.M. Tabatabaei...]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.