Residential College | false |
Status | 已發表Published |
Fault detection and isolation and fault tolerant control of wind turbines using set-valued observers | |
P. Casau1![]() ![]() | |
2016-04-23 | |
Conference Name | 8th IFAC Symposium on Fault Detection, Supervision and Safety of Technical Processes (SAFEPROCESS) |
Source Publication | IFAC Proceedings Volumes (IFAC-PapersOnline)
![]() |
Volume | 45 |
Issue | 20 PART 1 |
Pages | 120-125 |
Conference Date | 8th IFAC Symposium on Fault Detection, Supervision and Safety of Technical Processes (SAFEPROCESS) |
Conference Place | Mexico City |
Country | Mexico |
Author of Source | Elsevier |
Abstract | Research on wind turbine Operations & Maintenance (O&M) procedures is critical to the expansion of Wind Energy Conversion systems (WEC). In order to reduce O&M costs and increase the lifespan of the turbine, we study the application of Set-Valued Observers (SVO) to the problem of Fault Detection and Isolation (FDI) and Fault Tolerant Control (FTC) of wind turbines, by taking advantage of the recent advances in SVO theory for model invalidation. A simple wind turbine model is presented along with possible faulty scenarios. The FDI algorithm is built on top of the described model, taking into account process disturbances, uncertainty and sensor noise. The FTC strategy takes advantage of the proposed FDI algorithm, enabling the controller reconfiguration shortly after fault events. Additionally, a robust controller is designed so as to increase the wind turbine's performance during low severity faults. Finally, the FDI algorithm is assessed within a publicly available benchmark model, using Monte-Carlo simulation runs. |
DOI | 10.3182/20120829-3-MX-2028.00214 |
URL | View the original |
Language | 英語English |
Scopus ID | 2-s2.0-84867069688 |
Fulltext Access | |
Citation statistics | |
Document Type | Conference paper |
Collection | DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING |
Corresponding Author | P. Casau |
Affiliation | 1.Institute for Systems and Robotics - Instituto Superior T ́ecnico, Av.Rovisco Pais, 1, 1049-001 Lisboa, Portuga 2.Aalborg University, 9220 Aalborg East, Denmark 3.Faculty for Science and Technology, University of Macau, Taipa,Macau |
Recommended Citation GB/T 7714 | P. Casau,P. Rosa,S.M. TabatabaeipourS.M.,et al. Fault detection and isolation and fault tolerant control of wind turbines using set-valued observers[C]. Elsevier, 2016, 120-125. |
APA | P. Casau., P. Rosa., S.M. TabatabaeipourS.M.., & C. Silvestre (2016). Fault detection and isolation and fault tolerant control of wind turbines using set-valued observers. IFAC Proceedings Volumes (IFAC-PapersOnline), 45(20 PART 1), 120-125. |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment