Residential College | false |
Status | 已發表Published |
Microneedle-assisted dual delivery of PUMA gene and celastrol for synergistic therapy of rheumatoid arthritis through restoring synovial homeostasis | |
Hua, Peng; Liang, Ruifeng; Yang, Suleixin; Tu, Yanbei; Chen, Meiwan![]() ![]() | |
2024-06 | |
Source Publication | Bioactive Materials
![]() |
ISSN | 2452-199X |
Volume | 36Pages:83-95 |
Abstract | Abnormal proliferation of aggressive fibroblast-like synoviocytes (FLS) and perpetuate synovial inflammation can inevitably accelerate the progression of rheumatoid arthritis (RA). Herein, a strategy of simultaneously promoting FLS apoptosis and inhibiting inflammation as mediated by macrophages is proposed to restore synovial homeostasis for effective RA therapy. A hyaluronic acid-based dissolvable microneedle (MN) is fabricated for transdermal delivery of dual human serum albumin (HSA)-contained biomimetic nanocomplexes to regulate RA FLS and macrophages. Upon skin insertion, dual nanocomplexes are released rapidly from the MN and accumulate in RA joint microenvironment through both passive and active targeting as mediated by HSA. Thioketal-crosslinked fluorinated polyethyleneimine 1.8 K (PF) was constructed to bind the plasmid encoding pro-apoptotic gene PUMA with HSA coating layer (PF/pPUMA@HSA, TPH). TPH nanocomplexes can upregulate PUMA through RA FLS transfection to trigger efficient apoptosis. Also, HSA nanocomplexes encapsulating the classic anti-inflammatory natural product celastrol (Cel@HSA, CH) can inhibit inflammation of macrophages through blocking NF-κB pathway activation. TPH/CH MN can deplete RA FLS and inhibit M1 macrophage activation, suppress synovial hyperplasia as well as reduce bone and cartilage erosion in a collagen-induced arthritis (CIA) mouse model, demonstrating a promising strategy for efficient RA treatment. |
Keyword | Rheumatoid Arthritis Puma Celastrol Anti-inflammation Fibroblast-like Synoviocyte Apoptosis |
DOI | 10.1016/j.bioactmat.2024.02.030 |
URL | View the original |
Indexed By | SCIE |
Language | 英語English |
WOS Research Area | Engineering ; Materials Science |
WOS Subject | Engineering, Biomedical ; Materials Science, bioMaterials |
WOS ID | WOS:001188970000001 |
Publisher | KEAI PUBLISHING LTD, 16 DONGHUANGCHENGGEN NORTH ST, BEIJING, DONGCHENG DISTRICT 100717, PEOPLES R CHINA |
Scopus ID | 2-s2.0-85186386236 |
Fulltext Access | |
Citation statistics | |
Document Type | Journal article |
Collection | THE STATE KEY LABORATORY OF QUALITY RESEARCH IN CHINESE MEDICINE (UNIVERSITY OF MACAU) Institute of Chinese Medical Sciences |
Corresponding Author | Chen, Meiwan |
Affiliation | State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences, University of Macau, Macau SAR, China |
First Author Affilication | Institute of Chinese Medical Sciences |
Corresponding Author Affilication | Institute of Chinese Medical Sciences |
Recommended Citation GB/T 7714 | Hua, Peng,Liang, Ruifeng,Yang, Suleixin,et al. Microneedle-assisted dual delivery of PUMA gene and celastrol for synergistic therapy of rheumatoid arthritis through restoring synovial homeostasis[J]. Bioactive Materials, 2024, 36, 83-95. |
APA | Hua, Peng., Liang, Ruifeng., Yang, Suleixin., Tu, Yanbei., & Chen, Meiwan (2024). Microneedle-assisted dual delivery of PUMA gene and celastrol for synergistic therapy of rheumatoid arthritis through restoring synovial homeostasis. Bioactive Materials, 36, 83-95. |
MLA | Hua, Peng,et al."Microneedle-assisted dual delivery of PUMA gene and celastrol for synergistic therapy of rheumatoid arthritis through restoring synovial homeostasis".Bioactive Materials 36(2024):83-95. |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment