Optic Nerve Stimulation System with Adaptive Wireless Powering and Data Telemetry
Li, Xing; Lu, Yan; Meng, Xiaodong; Tsui, Chi-Ying; Ki, Wing-Hung
2017-12
Source PublicationMICROMACHINES
ISSN2072-666X
Volume8Issue:12
Abstract

To treat retinal degenerative diseases, a transcorneal electrical stimulation-based system is proposed, which consists of an eye implant and an external component. The eye implant is wirelessly powered and controlled by the external component to generate the required bi-polar current pattern for transcorneal stimulation with an amplitude range of 5 A to 320 A, a frequency range of 10 Hz to 160 Hz and a duty ratio range of 2.5% to 20%. Power delivery control includes power boosting in preparation for stimulation, and normal power regulation that adapts to both coupling and load variations. Only one pair of coils is used for both the power link and the bi-directional data link. Except for the secondary coil, the eye implant is fully integrated on chip and is fabricated using UMC (United Microelectronics Corporation, Hsinchu, Taiwan) 0.13 m complementary metal-oxide-semiconductor (CMOS) process with a size of 1.5 mm x 1.5 mm. The secondary coil is fabricated on a printed circuit board (PCB) with a diameter of only 4.4 mm. After coating with biocompatible silicone, the whole implant has dimensions of 6 mm in diameter with a thickness of less than 1 mm. The whole device can be put onto the sclera and beneath the eye's conjunctiva. System functionality and electrical performance are demonstrated with measurement results.

KeywordWireless Power Transfer (Wpt) Data Telemetry Implantable Medical Device (Imd) Neural Stimulation
DOI10.3390/mi8120368
URLView the original
Indexed BySCIE
Language英語English
WOS Research AreaScience & Technology - Other Topics ; Instruments & Instrumentation
WOS SubjectNanoscience & Nanotechnology ; Instruments & Instrumentation
WOS IDWOS:000419185700028
PublisherMDPI AG
The Source to ArticleWOS
Scopus ID2-s2.0-85039544915
Fulltext Access
Citation statistics
Document TypeJournal article
CollectionUniversity of Macau
Recommended Citation
GB/T 7714
Li, Xing,Lu, Yan,Meng, Xiaodong,et al. Optic Nerve Stimulation System with Adaptive Wireless Powering and Data Telemetry[J]. MICROMACHINES, 2017, 8(12).
APA Li, Xing., Lu, Yan., Meng, Xiaodong., Tsui, Chi-Ying., & Ki, Wing-Hung (2017). Optic Nerve Stimulation System with Adaptive Wireless Powering and Data Telemetry. MICROMACHINES, 8(12).
MLA Li, Xing,et al."Optic Nerve Stimulation System with Adaptive Wireless Powering and Data Telemetry".MICROMACHINES 8.12(2017).
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Li, Xing]'s Articles
[Lu, Yan]'s Articles
[Meng, Xiaodong]'s Articles
Baidu academic
Similar articles in Baidu academic
[Li, Xing]'s Articles
[Lu, Yan]'s Articles
[Meng, Xiaodong]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Li, Xing]'s Articles
[Lu, Yan]'s Articles
[Meng, Xiaodong]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.