Residential College | false |
Status | 已發表Published |
Sub-μW QRS detection processor using quadratic spline wavelet transform and maxima modulus pair recognition for power-efficient wireless arrhythmia monitoring | |
Chio-In Ieong2; Pui-In Mak2; Mang-I Vai2; Rui P. Martins1,2 | |
2016-03-07 | |
Conference Name | 21st Asia and South Pacific Design Automation Conference (ASP-DAC) |
Source Publication | 2016 21st Asia and South Pacific Design Automation Conference (ASP-DAC) |
Volume | 25-28-January-2016 |
Pages | 21-22 |
Conference Date | JAN 25-28, 2016 |
Conference Place | Macau, China |
Abstract | This paper describes a power-efficient processor for extracting the timing of QRS complex from digitized ECG, based on the hardware-efficient architecture of quadratic spline wavelet transform (QSWT) and maxima modulus pair recognition (MMPR). The processor succeeds in saving the wireless system's power by 6×. |
DOI | 10.1109/ASPDAC.2016.7427982 |
URL | View the original |
Indexed By | SCIE |
Language | 英語English |
WOS Research Area | Automation & Control Systems ; Engineering |
WOS Subject | Automation & Control Systems ; Engineering, Electrical & Electronic |
WOS ID | WOS:000384642200011 |
Scopus ID | 2-s2.0-84996836060 |
Fulltext Access | |
Citation statistics | |
Document Type | Conference paper |
Collection | THE STATE KEY LABORATORY OF ANALOG AND MIXED-SIGNAL VLSI (UNIVERSITY OF MACAU) Faculty of Science and Technology DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING |
Affiliation | 1.Instituto Superior Técnico, Universidade de Lisboa, Portugal 2.State-Key Laboratory of Analog and Mixed-Signal VLSI and FST-ECE, University of Macau, Macao, China |
First Author Affilication | Faculty of Science and Technology |
Recommended Citation GB/T 7714 | Chio-In Ieong,Pui-In Mak,Mang-I Vai,et al. Sub-μW QRS detection processor using quadratic spline wavelet transform and maxima modulus pair recognition for power-efficient wireless arrhythmia monitoring[C], 2016, 21-22. |
APA | Chio-In Ieong., Pui-In Mak., Mang-I Vai., & Rui P. Martins (2016). Sub-μW QRS detection processor using quadratic spline wavelet transform and maxima modulus pair recognition for power-efficient wireless arrhythmia monitoring. 2016 21st Asia and South Pacific Design Automation Conference (ASP-DAC), 25-28-January-2016, 21-22. |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment