UM  > Faculty of Health Sciences
Status已發表Published
Comparison of different Tc-99m-MAA imaging protocols for Y-90 SIRT treatment planning
Mingren Feng3; Tiantian Li3; Nien-Yun Wu1,2; Greta Mok3,4
2018
Conference Name2017 IEEE Nuclear Science Symposium and Medical Imaging Conference
Source PublicationJ Nucl Med
Volume59
Conference DateOctober 21 – 28, 2017
Conference PlaceAtlanta, GA, USA
Abstract

Objectives: : Previous studies showed that conventional planar Tc-99m MAA imaging overestimates lung shunt fraction (LSF) in Y-90 selective internal radiation therapy (SIRT), and SPECT/CT would provide more accurate result. However, the temporal mismatch between SPECT and conventional helical CT (HCT) may lead to respiratory artifacts from the CT-based attenuation correction. This simulation study aimed to investigate the potential improvement on SIRT treatment planning using SPECT/CT with different attenuation maps for attenuation correction, as compared to planar imaging.

Methods: The 4D Extended Cardiac Torso (XCAT) phantoms with Tc-99m MAA activity distribution and 3 anatomical variations were used in this study. For each phantom, respiratory motion of 2 and 4 cm and LSFs of 5%, 10%, 15% and 20% were modeled. We simulated a spherical liver tumor with tumor to normal liver (T/N) ratio of 11.43 and radius of 1.5 cm near the boundary of liver and lungs. An analytical projector was used to simulate anterior and posterior planar projections of the chest and abdomen region (5 min/view), and 128 projections with 30 s/view over 360 for SPECT/CT, both modeling attenuation, scatter and geometric collimator-detector-response. Three different attenuation maps were evaluated for SPECT: (i) HCT captured at end-inspiration (HCT-IN), (ii) cine averaged CT (CACT) and (iii) HCT captured at end-expiration (HCT-EX). Projections were reconstructed by OS-EM algorithm with 20 iterations and 16 subsets with full compensations using different attenuation maps. The regions-of-interest of lungs and liver were manually drawn on the planar geometric mean images (2D), while they were drawn on the corresponding CT maps (3D) for SPECT to calculate the LSF, using an open-source software ITK-SNAP. The tumor was delineated from the CT maps for different SPECT protocols to calculate the T/N ratios. The errors of LSF and T/N ratio of different imaging protocols were measured.

Results: The LSF errors were generally larger for planar imaging and HCT-IN while relatively smaller for CACT and HCT-EX. For example, for 2 cm motion and 10% LSF, the LSF errors of HCT-IN, CACT, HCT-EX and planar were 77.71±3.89%, 45.19±3.76%, -29.09±3.10% and 45.22±12.36%, while the T/N errors were smallest for CACT followed by HCT-EX, and HCT-IN, i.e., 3.89±1.31%, -9.42±2.21% and -15.01±2.19% respectively. The differences among different protocols are generally higher for lower LSF and higher respiratory motion amplitude.

Conclusions: SPECT/CT protocol improves the Y-90 SIRT treatment planning accuracy as compared to planar. HCT-EX or CACT would be recommended for Tc-99m-MAA SPECT/CT attenuation correction to avoid the respiratory artifacts. Further studies to investigate how LSF and T/N ratio impact administrated dosage and radiation dose on critical organs and tumors are warranted.

Indexed BySCIE
Language英語English
WOS Research AreaRadiology, Nuclear Medicine & Medical Imaging
WOS SubjectRadiology, Nuclear Medicine & Medical Imaging
WOS IDWOS:000467489902426
Fulltext Access
Citation statistics
Document TypeConference paper
CollectionFaculty of Health Sciences
DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING
Affiliation1.Department of Biomedical Imaging and Radiological Sciences National Yang Ming University Taipei Taiwan
2.Department of Nuclear Medicine Taipei Veterans General Hospital Taipei Taiwan
3.Department of Electrical and Computer Engineering University of Macau Taipa Macao
4.Department of Radiology University of Massachusetts Medical School Worcester MA United States
First Author AffilicationUniversity of Macau
Recommended Citation
GB/T 7714
Mingren Feng,Tiantian Li,Nien-Yun Wu,et al. Comparison of different Tc-99m-MAA imaging protocols for Y-90 SIRT treatment planning[C], 2018.
APA Mingren Feng., Tiantian Li., Nien-Yun Wu., & Greta Mok (2018). Comparison of different Tc-99m-MAA imaging protocols for Y-90 SIRT treatment planning. J Nucl Med, 59.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Mingren Feng]'s Articles
[Tiantian Li]'s Articles
[Nien-Yun Wu]'s Articles
Baidu academic
Similar articles in Baidu academic
[Mingren Feng]'s Articles
[Tiantian Li]'s Articles
[Nien-Yun Wu]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Mingren Feng]'s Articles
[Tiantian Li]'s Articles
[Nien-Yun Wu]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.