UM
Residential Collegefalse
Status已發表Published
An implantable circularly polarized patch antenna design for pacemaker monitoring based on analysis of quality factor
Yang, Z.-J.; Zhu, L.; Xiao, S.
2018-10-01
Source PublicationIEEE Transactions on Antennas and Propagation
ISSN0018-926X
Pages5180-5192
Abstract

A design approach is presented in this paper to develop an implantable circularly polarized (CP) microstrip patch antenna (MPA) embedded in a lossy material by addressing its total quality factor (QT ). To achieve it, the effect of high-loss tissue on effective relative permittivity and loss tangent of MPA has been thoroughly investigated. To the authors’ best knowledge, it is the first time that the exact values of QT with respect to the high-loss tissue and embedded depth are studied and applied to design an implantable MPA. As the calculated QT is confirmed in simulation, one can understand that an implantable MPA is actually a lossy resonator with extremely low QT . As such, CP radiation can be achieved by enlarging its truncated area to appropriately separate two degenerate modes in such high-loss environment. The designed implantable MPA is then exhibited to achieve a broad impedance bandwidth, wide 3 dB axial ratio bandwidth and beamwidth, and high realized gain at 2.4 GHz industrial, scientific, and medical band. After the studies of sensitivity, biocompatible materials, and model integrity are carried out, the designed implantable MPA is fabricated and tested. Simulations are accompanied by measurements with good agreement, thus underlying the importance of our approach.

KeywordImplantable Antenna Microstrip Patch Antenna
DOI10.1109/TAP.2018.2862242
Language英語English
WOS IDWOS:000446652300022
The Source to ArticlePB_Publication
Scopus ID2-s2.0-85050980530
Fulltext Access
Citation statistics
Document TypeJournal article
CollectionUniversity of Macau
Recommended Citation
GB/T 7714
Yang, Z.-J.,Zhu, L.,Xiao, S.. An implantable circularly polarized patch antenna design for pacemaker monitoring based on analysis of quality factor[J]. IEEE Transactions on Antennas and Propagation, 2018, 5180-5192.
APA Yang, Z.-J.., Zhu, L.., & Xiao, S. (2018). An implantable circularly polarized patch antenna design for pacemaker monitoring based on analysis of quality factor. IEEE Transactions on Antennas and Propagation, 5180-5192.
MLA Yang, Z.-J.,et al."An implantable circularly polarized patch antenna design for pacemaker monitoring based on analysis of quality factor".IEEE Transactions on Antennas and Propagation (2018):5180-5192.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Yang, Z.-J.]'s Articles
[Zhu, L.]'s Articles
[Xiao, S.]'s Articles
Baidu academic
Similar articles in Baidu academic
[Yang, Z.-J.]'s Articles
[Zhu, L.]'s Articles
[Xiao, S.]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Yang, Z.-J.]'s Articles
[Zhu, L.]'s Articles
[Xiao, S.]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.