Residential College | false |
Status | 已發表Published |
Evaluation of Stationary and Semi-stationary Acquisitions in a Dual-head Multi-pinhole Collimator for Myocardial Perfusion SPECT | |
Yan, PY1; Chen, L1; Tsui, BMW2; Mok, S. P.1 | |
2014-11 | |
Publisher | IEEE |
Publication Place | Seattle, WA, USA |
Conference Place | 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Seattle, WA, USA, 2014 |
Abstract | This study investigates the performance of different stationary and semi-stationary multi-pinhole (MPH) designs with a dual-head L-mode configuration as compared to that of a conventional low-energy high-resolution (LEHR) collimator for myocardial perfusion (MP) single-photon emission computed tomography (SPECT). The target field of view for the heart was 16 cm with a target resolution of 1 cm. The design parameters were determined by maximizing the detection efficiency based on the system constraints. Three stationary designs (L-modes I to III) and semi-stationary designs (S-modes I to III) with four detector positions (i.e., 2 L-mode positions at various angles apart) were evaluated. We used the XCAT phantom with 99mTc-sestamibi distribution and a three-dimensional analytical MPH/LEHR projector to generate noise-free and noisy projections, which were reconstructed using the maximum-likelihood expectation-maximization algorithm with up to 180 updates. A two-dimensional (2D) region of interest with 32 × 32 pixels covering the central axial slice of the left ventricle was analyzed using normalized mean-squared error (NMSE), normalized standard deviation (NSD), and a 2D bias map. The optimized design parameters are 12 pinholes, an acceptance angle of 51°, an aperture size of 4.6 |
Keyword | Single-photon Emission Computed Tomography (Spect) Myocardial Perfusion Multi-pinhole Stationary Acquisition |
Pages | 675-685 |
Language | 英語English |
Document Type | Conference proceedings |
Collection | DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING |
Corresponding Author | Mok, S. P. |
Affiliation | 1.University of Macau 2.Johns Hopkins University |
First Author Affilication | University of Macau |
Recommended Citation GB/T 7714 | Yan, PY,Chen, L,Tsui, BMW,et al. Evaluation of Stationary and Semi-stationary Acquisitions in a Dual-head Multi-pinhole Collimator for Myocardial Perfusion SPECT[C]. Seattle, WA, USA:IEEE, 2014. |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment