Residential Collegefalse
Status已發表Published
Evaluation of Stationary and Semi-stationary Acquisitions in a Dual-head Multi-pinhole Collimator for Myocardial Perfusion SPECT
Yan, PY1; Chen, L1; Tsui, BMW2; Mok, S. P.1
2014-11
PublisherIEEE
Publication PlaceSeattle, WA, USA
Conference Place2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Seattle, WA, USA, 2014
Abstract

This study investigates the performance of different stationary and semi-stationary multi-pinhole (MPH) designs with a dual-head L-mode configuration as compared to that of a conventional low-energy high-resolution (LEHR) collimator for myocardial perfusion (MP) single-photon emission computed tomography (SPECT). The target field of view for the heart was 16 cm with a target resolution of 1 cm. The design parameters were determined by maximizing the detection efficiency based on the system constraints. Three stationary designs (L-modes I to III) and semi-stationary designs (S-modes I to III) with four detector positions (i.e., 2 L-mode positions at various angles apart) were evaluated. We used the XCAT phantom with 99mTc-sestamibi distribution and a three-dimensional analytical MPH/LEHR projector to generate noise-free and noisy projections, which were reconstructed using the maximum-likelihood expectation-maximization algorithm with up to 180 updates. A two-dimensional (2D) region of interest with 32 × 32 pixels covering the central axial slice of the left ventricle was analyzed using normalized mean-squared error (NMSE), normalized standard deviation (NSD), and a 2D bias map. The optimized design parameters are 12 pinholes, an acceptance angle of 51°, an aperture size of 4.6

KeywordSingle-photon Emission Computed Tomography (Spect) Myocardial Perfusion Multi-pinhole Stationary Acquisition
Pages675-685
Language英語English
Document TypeConference proceedings
CollectionDEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING
Corresponding AuthorMok, S. P.
Affiliation1.University of Macau
2.Johns Hopkins University
First Author AffilicationUniversity of Macau
Recommended Citation
GB/T 7714
Yan, PY,Chen, L,Tsui, BMW,et al. Evaluation of Stationary and Semi-stationary Acquisitions in a Dual-head Multi-pinhole Collimator for Myocardial Perfusion SPECT[C]. Seattle, WA, USA:IEEE, 2014.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Yan, PY]'s Articles
[Chen, L]'s Articles
[Tsui, BMW]'s Articles
Baidu academic
Similar articles in Baidu academic
[Yan, PY]'s Articles
[Chen, L]'s Articles
[Tsui, BMW]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Yan, PY]'s Articles
[Chen, L]'s Articles
[Tsui, BMW]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.