UM
Residential Collegefalse
Status已發表Published
Interpolated Average CT for Cardiac PET/CT Attenuation Correction
Mok, S. P.; Ho, Y. T.; Yang, B. H.; Wu, T. H
2016-10-01
Source PublicationJournal of Nuclear Cardiology
ISSN1532-6551
Pages1072-1079
Abstract

Background. Previously, we proposed interpolated averaged CT (IACT) for improved attenuation correction (AC) in thoracic PET/CT. This study aims to evaluate its feasibility and effectiveness on cardiac PET/CT. Methods. We simulated 18F-FDG distribution using the XCAT phantom with normal and abnormal cardiac uptake. Average activity and attenuation maps represented static PET and respiration average CT (ACT), respectively, while the attenuation maps of end-inspiration/ expiration represented 2 helical CTs (HCT). IACT was obtained by averaging the 2 extreme phases and the interpolated phases generated between them. Later, we recruited 4 patients who were scanned 1 hr post 315-428 MBq 18F-FDG injection. Simulated and clinical PET sinograms were reconstructed with AC using (1) HCT, (2) IACT, and (3) ACT. Polar plots and the 17-segment plots were analyzed. Two regions-of-interest were drawn on lesion and background area to obtain the intensity ratio (IR). Results. Polar plots of PETIACT-AC were more similar to PETACT-AC in both simulation and clinical data. Artifacts were observed in various segments in PETHCT-AC. IR differences of HCT as compared to the phantom were up to ~20%. Conclusions. IACT-AC reduced respiratory artifacts and improved PET/CT matching similarly to ACT-AC. It is a promising low-dose alternate of ACT for cardiac PET/CT.

KeywordPet/ct Cardiac Imaging Attenuation Correction Respiratory Artifacts
DOI10.1007/s12350-015-0140-5
Language英語English
The Source to ArticlePB_Publication
Fulltext Access
Citation statistics
Document TypeJournal article
CollectionUniversity of Macau
Corresponding AuthorMok, S. P.
Recommended Citation
GB/T 7714
Mok, S. P.,Ho, Y. T.,Yang, B. H.,et al. Interpolated Average CT for Cardiac PET/CT Attenuation Correction[J]. Journal of Nuclear Cardiology, 2016, 1072-1079.
APA Mok, S. P.., Ho, Y. T.., Yang, B. H.., & Wu, T. H (2016). Interpolated Average CT for Cardiac PET/CT Attenuation Correction. Journal of Nuclear Cardiology, 1072-1079.
MLA Mok, S. P.,et al."Interpolated Average CT for Cardiac PET/CT Attenuation Correction".Journal of Nuclear Cardiology (2016):1072-1079.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Mok, S. P.]'s Articles
[Ho, Y. T.]'s Articles
[Yang, B. H.]'s Articles
Baidu academic
Similar articles in Baidu academic
[Mok, S. P.]'s Articles
[Ho, Y. T.]'s Articles
[Yang, B. H.]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Mok, S. P.]'s Articles
[Ho, Y. T.]'s Articles
[Yang, B. H.]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.