Simulation test of granite alteration in HDR reservoir using flow system autoclave
Yamasaki N.; Wang Y.; Yanagisawa K.; Feng Q.; Nishiuchi S.; Ishida T.; Tsuchiya N.; Nakatsuka K.; Takahashi H.; Hayashi K.
1999
Source PublicationGeothermal Science and Technology
ISSN08905363
Volume6Issue:1-4Pages:299-314
Abstract

A tube reactor autoclave equipped with pH meter with a temperature gradient for considering the flow system in multi cracks of hot dry or wet rock has been developed. The results using this simulation test showed a maximum dissolution regions at the temperature between 250-320°C and the deposition regions above 330°C. The dramatic change from dissolution to deposition occurred at 330°C. These results were supported by the apparent solubility of granite and silica. The dissolution-deposition under the flow system was mainly proceeded by alteration of feldspar around 200°C, and quartz above 300°C. The deposition mineral was low quatz at the place above 330°C with flow direction from low to high temperature, however, cristobaite from high to low temperature. The alteration of feldspar in granite is easily occurred around at 200°C to form zeolite and clay minerals. Mica in granite is most stable mineral and the alteration could not be observed besides deposit minerals on the surface.

KeywordAlteration Flow System Autoclave Granite Hdr Hydrothermal
URLView the original
Language英語English
Scopus ID2-s2.0-0032818528
Fulltext Access
Citation statistics
Document TypeJournal article
CollectionUniversity of Macau
AffiliationTohoku University
Recommended Citation
GB/T 7714
Yamasaki N.,Wang Y.,Yanagisawa K.,et al. Simulation test of granite alteration in HDR reservoir using flow system autoclave[J]. Geothermal Science and Technology, 1999, 6(1-4), 299-314.
APA Yamasaki N.., Wang Y.., Yanagisawa K.., Feng Q.., Nishiuchi S.., Ishida T.., Tsuchiya N.., Nakatsuka K.., Takahashi H.., & Hayashi K. (1999). Simulation test of granite alteration in HDR reservoir using flow system autoclave. Geothermal Science and Technology, 6(1-4), 299-314.
MLA Yamasaki N.,et al."Simulation test of granite alteration in HDR reservoir using flow system autoclave".Geothermal Science and Technology 6.1-4(1999):299-314.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Yamasaki N.]'s Articles
[Wang Y.]'s Articles
[Yanagisawa K.]'s Articles
Baidu academic
Similar articles in Baidu academic
[Yamasaki N.]'s Articles
[Wang Y.]'s Articles
[Yanagisawa K.]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Yamasaki N.]'s Articles
[Wang Y.]'s Articles
[Yanagisawa K.]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.